      Optimum neutron energy simulation in treatment of head and neck cancer at different depths in the BNCT method

      (ندگان)پدیدآور
      Sabery Balajaddeh, FatemeGolshanian, MohadesehZanganeh, Vahid
      Thumbnail
      نوع مدرک
      Text
      Conference Proceedings
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Recently head and neck cancer has pay attention to many researchers. Its therapeutic methods include surgery, chemotherapy, radiotherapy and Boron neutron capture therapy (BNCT). BNCT is better than conventional radiotherapy because it targets the tumor cell. This method involves two steps of infusion of stable 10B and then neutron radiation with a suitable intensity and energy. The BNCT in combination with boronphenylalanine (BPA) and borocaptate sodium (BSH) that was make using the epithermal neutron. BSH and PBA are used as 10B carriers. Epithermal neutrons reach to thermal transiting through tissues of the body. When 10B absorbed thermal neutrons, the α and 7Li particles produced in the 10B (n, α) 7Li reaction are of high linear energy. Transfer radiation have a short range of one cell diameter. Materials and Methods: Monte Carlo simulations were performed with MCNPX2.6 and RO31 MIRD phantom. The neutron source was employed the surface disk with 10 diameters and the range of energy was considered from 1ev-10Kev. The results of neutron and gamma dose at various depths was calculated using tally F4 and F6 in MCNPX2.6 code. Results: Relative Dose was obtained at various depths based on energy changes for gamma, fast and thermal neutron. The results of this study have shown increases of optimum energy as the tumor get deeper respect to the skin. In addition, an analytical relation was proposed for energy optimization with the position of the tumor. Conclusion: The optimum neutron energy dependence was investigated for neck tumor in different depths. These results provide useful information to the physicians to choice best optimum energy neutron beam in BNCT method.
      کلید واژگان
      Boron neutron capture therapy (BNCT)
      Optimize energy relative to depth at BNCT
      Gamma and fast neutron doses

      شماره نشریه
      12
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Department of physics, Sciences Facility, Golestan University P. O. Box 49138-15759, Gorgan, Iran.
      Department of reactor, nuclear science and technology research institute, Tehran, Iran
      Department of physics, Sciences Facility, Golestan University P. O. Box 49138-15759, Gorgan, Iran.

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2018.11930
      http://ijmp.mums.ac.ir/article_11930.html
      https://iranjournals.nlai.ir/handle/123456789/324329

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب