    Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

    (ندگان)پدیدآور
    Asadinezhad, MohsenBahreyni Toossi, Mohammad TaghiNouri, Mina
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    992.7کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cities in 12 provinces of Iran. A calibrated pencil-shaped ionization chamber, standard head and body CT dosimetry phantoms and a radiation monitor were used to determine and calculate Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP). The DLP-based estimates of effective dose were derived using effective dose conversion coefficients. Results: The nCTDIw values for head phantoms fell within the range of 22.05-168.38 and 43.77-426.69 µGy/mAs for 5 and 10mm slice thicknesses, respectively. These values for body phantom were 4.65-146.39 and 9.43-308.92 µGy/mAs for 5 and 10mm slice thicknesses, respectively. The third quartile of CTDIvol and DLP values for head CT examinations were 49.85 mGy and 1161.00 mGy-cm, respectively. The body CT examinations had the values of 8.89 mGy and 370.97 mGy-cm, respectively. The findings of this study revealed that the above-mentioned values can be considered as national diagnostic reference levels for head and body CT examinations in Iran. Conclusion: The results of the current study suggested that there is a need to re-assess DRLs for CT examinations at regular time intervals by the appropriate regulatory authority which can improve the continuous performance of CT scanners in Iran.
    کلید واژگان
    Computed Tomography
    Iran
    Radiation Dosimetry
    Computed Tomography (CT)
    Medical Physics
    Radiation Detection & Measurement

    شماره نشریه
    1
    تاریخ نشر
    2019-01-01
    1397-10-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Radiology Technology, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
    Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
    Department of Radiology Technology, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2018.33100.1402
    http://ijmp.mums.ac.ir/article_11500.html
    https://iranjournals.nlai.ir/handle/123456789/324281

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب