      Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

      (ندگان)پدیدآور
      Bahreyni Toossi, Mohammad TaghiMomen Nezhad, MehdiHashemi, Seyed Mohammad
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      693.1کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. Material and Methods: In this study, the MCNP-4C Monte Carlo code was used to simulate the electron beams generated by a Neptun 10 PC linear accelerator. The depth dose curves and related parameters to depth dose and beam profiles were calculated for 6, 8 and 10 MeV electron beams with different field sizes and these data were compared with the corresponding measured values. The actual dosimetry was performed by employing a Welhofer-Scanditronix dose scanning system, semiconductor detectors and ionization chambers. Results: The result showed good agreement (better than 2%) between calculated and measured depth doses and lateral dose profiles for all energies in different field sizes. Also good agreements were achieved between calculated and measured related electron beam parameters such as E0, Rq, Rp and R50. Conclusion: The simulated model of the linac developed in this study is capable of computing electron beam data in a water phantom for different field sizes and the resulting data can be used to predict the dose distributions in other complex geometries.
      کلید واژگان
      Simulation
      Monte Carlo
      Linear Accelerator
      Dosimetry
      Medical Application of Computer Simulation
      Medical Physics
      Physics of Radiotherapy
      Radiation Detection & Measurement

      شماره نشریه
      2
      تاریخ نشر
      2009-06-01
      1388-03-11
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Professor, Medical Physics Research Center, Bu-Ali Research Institute, Mashhad University of Medical Sciences, Mashhad, Iran
      Ph.D., Linear Accelerator Dept., Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
      M.Sc., Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2009.7291
      http://ijmp.mums.ac.ir/article_7291.html
      https://iranjournals.nlai.ir/handle/123456789/324205

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب