    De-Noising SPECT Images from a Typical Collimator Using Wavelet Transform

    (ندگان)پدیدآور
    Babapour Mofrad, FarshidAbbaspour Tehrani-Fard, AliEbrahimi, BabakSardari, Dariush
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    911.3کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: SPECT is a diagnostic imaging technique the main disadvantage of which is the existence of Poisson noise. So far, different methods have been used by scientists to improve SPECT images. The Wavelet Transform is a new method for de-noising which is widely used for noise reduction and quality enhancement of images. The purpose of this paper is evaluation of noise reduction in SPECT images by wavelet. Material and Methods: To calculate and simulate noise in images, it is common in nuclear medicine to use Monte Carlo techniques. The SIMIND software was used to simulate SPECT images in this research. The simulated and real images formed using the current typical (hexagonal) collimator were de-noised by different types of wavelets. Results: The best type of wavelet was selected for SPECT images. The results demonstrated that the best type of wavelet in the simulated and real images increased Signal to Noise Ratio (SNR) by 33% and 45% respectively. Also, Coefficient of Variation (CV) decreased by 77% and 71% respectively, while Contrast of Recovery (CR) was reduced by only 4% and 9% respectively. Conclusion: Comparing the results for real SPECT images in this paper with previously acquired results in real PET images, it can be concluded that the images of both nuclear medicine systems using Wavelet Transform differ in SNR and CR by only 5% and 7% respectively, and in CV by about 20%. Therefore, wavelet transform is applicable for nuclear medicine image de-noising.
    کلید واژگان
    SPECT
    SIMIND
    Collimator
    Wavelet Transform
    De-noising
    Medical Application of Computer Simulation
    Medical Physics
    Physics of Nuclear Medicine

    شماره نشریه
    34
    تاریخ نشر
    2009-12-01
    1388-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Ph.D., Candidate, Faculty of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
    Assistant Professor, Faculty of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
    M.Sc., Faculty of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
    Assistant Professor, Faculty of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2009.7280
    http://ijmp.mums.ac.ir/article_7280.html
    https://iranjournals.nlai.ir/handle/123456789/324196

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب