• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 7, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 7, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter

    (ندگان)پدیدآور
    Sadoughi, Hamid RezaAllahverdi, MahmoodNedaei, HasanJaberi, RaminEsfahani, MahbodShirazi, Alireza
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    804.9کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made. Paired cubes in the phantom representing bladder and prostate and a cylindrical container representing rectum were filled with MAGIC gel and placed in the anthropomorphic pelvic phantom. The phantom was irradiated with four beams as planned using a treatment planning system (TPS). Magnetic resonance transverse relaxation rate images were acquired and turned into dose distribution maps using a calibration curve. This calibration curve was obtained by linear fitting to R2 values of 4 test tubes against their given known doses. Image processing and data analysis were performed in MATLAB7 software. The gel dosimeter was validated using an ionization chamber. Dose maps and dose volume histograms (DVHs) were compared with dose distributions and DVHs of the TPS. Results: Mean “distance-to-agreement" and mean “dose difference" were 2.98 mm and 6.2%, respectively, in the comparison of profiles obtained from ionization chamber and gel dosimetry. Mean relative difference of DVHs between gel dosimetry and TPS data were 3.04%, 10.4% and 11.7%, for prostate, bladder and rectum, respectively. Discussion and Conclusions: Gel dosimetry is a good method for three dimensional dosimetry although it has a low precision in high dose gradient regions. This method can be used for evaluation of complicated dose distribution accuracy in 3D conformal radiotherapy, especially in presence of heterogeneities.
    کلید واژگان
    3D gel dosimetry
    Prostate radiotherapy
    MAGIC polymer gel
    Bladder and rectum dose
    Medical Physics
    Physics of Radiotherapy
    Radiation Detection & Measurement

    شماره نشریه
    1
    تاریخ نشر
    2010-03-01
    1388-12-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    M.Sc. Student of Medical Physics, Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran
    Associate Professor, Medical Physics Dept., Tehran University of Medical Sciences, and Radiotherapy Physics Department of Cancer Institute, Tehran, Iran
    Assistant Professor, Radiotherapy Physics Dept., Cancer Institute, Tehran, Iran
    Radiotherapy Physicist, Radiotherapy Physics Dept., Cancer Institute, Tehran, Iran
    Radiotherapy Physicist, Radiotherapy Physics Dept., Cancer Institute, Tehran, Iran
    Associated Professor, Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2010.7270
    http://ijmp.mums.ac.ir/article_7270.html
    https://iranjournals.nlai.ir/handle/123456789/324191

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب