      A Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter

      (ندگان)پدیدآور
      Sadoughi, Hamid RezaAllahverdi, MahmoodNedaei, HasanJaberi, RaminEsfahani, MahbodShirazi, Alireza
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      804.9کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made. Paired cubes in the phantom representing bladder and prostate and a cylindrical container representing rectum were filled with MAGIC gel and placed in the anthropomorphic pelvic phantom. The phantom was irradiated with four beams as planned using a treatment planning system (TPS). Magnetic resonance transverse relaxation rate images were acquired and turned into dose distribution maps using a calibration curve. This calibration curve was obtained by linear fitting to R2 values of 4 test tubes against their given known doses. Image processing and data analysis were performed in MATLAB7 software. The gel dosimeter was validated using an ionization chamber. Dose maps and dose volume histograms (DVHs) were compared with dose distributions and DVHs of the TPS. Results: Mean “distance-to-agreement" and mean “dose difference" were 2.98 mm and 6.2%, respectively, in the comparison of profiles obtained from ionization chamber and gel dosimetry. Mean relative difference of DVHs between gel dosimetry and TPS data were 3.04%, 10.4% and 11.7%, for prostate, bladder and rectum, respectively. Discussion and Conclusions: Gel dosimetry is a good method for three dimensional dosimetry although it has a low precision in high dose gradient regions. This method can be used for evaluation of complicated dose distribution accuracy in 3D conformal radiotherapy, especially in presence of heterogeneities.
      کلید واژگان
      3D gel dosimetry
      Prostate radiotherapy
      MAGIC polymer gel
      Bladder and rectum dose
      Medical Physics
      Physics of Radiotherapy
      Radiation Detection & Measurement

      شماره نشریه
      1
      تاریخ نشر
      2010-03-01
      1388-12-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      M.Sc. Student of Medical Physics, Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran
      Associate Professor, Medical Physics Dept., Tehran University of Medical Sciences, and Radiotherapy Physics Department of Cancer Institute, Tehran, Iran
      Assistant Professor, Radiotherapy Physics Dept., Cancer Institute, Tehran, Iran
      Radiotherapy Physicist, Radiotherapy Physics Dept., Cancer Institute, Tehran, Iran
      Radiotherapy Physicist, Radiotherapy Physics Dept., Cancer Institute, Tehran, Iran
      Associated Professor, Medical Physics Dept., Tehran University of Medical Sciences, Tehran, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2010.7270
      http://ijmp.mums.ac.ir/article_7270.html
      https://iranjournals.nlai.ir/handle/123456789/324191

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب