      Extraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm

      (ندگان)پدیدآور
      Rafati, MehravarMokhtari Dizaji, ManijheSaberi, HojabrSoleimani, Effat
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      563.3کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was applied to the common carotid artery of ten healthy subjects and the longitudinal movement of the arterial wall was extracted in three cardiac cycles. Manual measurements were carried out to validate the automatic method. The maximum, minimum and average longitudinal displacements of the arterial wall were extracted from the automatic method and compared with the manual measurements, with 10 mm displacement of two blocks in first frame. Results: Paired t-test analysis showed no significant differences between the automatic and manual methods (p>0.05). There was significant correlation between the changes in the instantaneous longitudinal movement of the common carotid artery measured with the manual and automatic methods (correlation coefficient 0.97, p0.05). There was significant correlation between the changes in the instantaneous longitudinal movement of the common carotid artery measured with the manual and automatic methods (correlation coefficient 0.97, pDiscussion and Conclusion: This study shows that the block matching algorithm can automatically extract the longitudinal movement of the arterial wall from consecutive ultrasonic images.
      کلید واژگان
      Biomechanical Behavior of Artery
      Block Matching Algorithm
      Motion Detection
      Ultrasound
      Medical Engineering
      Medical Physics
      Sound and Ultrasound

      شماره نشریه
      3
      تاریخ نشر
      2011-09-01
      1390-06-10
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Ph.D. in Medical Physics, Medical Physics Dept., Tarbiat Modares University, Tehran, Iran
      Prof., Medical Physics Dept., Tarbiat Modares University, Tehran, Iran
      Associate Professor, Radiology Dept., Tehran University of Medical Sciences, Imaging Center of Imam Khomaini Hospital, Tehran, Iran
      Ph.D. Student in Medical Physics, Medical Physics Dept., Tarbiat Modares University, Tehran, Iran

      شاپا
      2345-3672
      URI
      https://dx.doi.org/10.22038/ijmp.2011.7229
      http://ijmp.mums.ac.ir/article_7229.html
      https://iranjournals.nlai.ir/handle/123456789/324161

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب