    Diagnostic Accuracy of Frozen Section in Comparison With Fine Needle Aspiration Cytology in Thyroid Lesions – A Prospective Study

    (ندگان)پدیدآور
    Kumar, MaheshPotekar, RatnakarRamling Yelikar, BalasahebPatil, VijayalaxmiKarigoudar, MaheshPande, Pankaj
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    813.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background and Objectives: Thyroid gland because of its superficial location is amenable to direct physical examination. Clinical assessment of thyroid lesions by means of physical examination, thyroid scans and ultrasonography is not completely reliable. Fine needle aspiration cytology (FNAC) is the most cost-effective, safe and an initial diagnostic test in the pre-operative evaluation of thyroid lesions. Many surgeons use intraoperative frozen section biopsies to confirm the diagnosis of FNAC and guide the extent of thyroidectomy. Therefore, the objective of the present study was to assess the diagnostic accuracy of frozen section in comparison with fine needle aspiration cytology and histopathology in thyroid lesions. Materials & Methods: Fine needle aspiration cytology and frozen section (FS) were evaluated in 59 patients. FNAC was classified as benign, malignant and suspicious, and FS was classified as benign, deferred and malignant. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for both FS and FNAC. Results: Out of 59 patients, 3 were positive for malignancy, 51 were benign, and five were suspicious on FNAC. Over all accuracy of fine needle aspiration cytology was 93%. Five were positive for malignancy, 50 were benign and 4 were “deferred" in frozen section. Over all accuracy of frozen section was 96%. Discussion: Fine needle aspiration cytology can be used primarily to select patient for surgery and frozen section can be employed to plan the extent of surgery. Frozen section had a good accuracy, sensitivity and negative predictive value compared to fine needle aspiration cytology.
    کلید واژگان
    Fine needle aspiration
    Cytology
    Frozen Section
    Thyroid Nodule

    شماره نشریه
    4
    تاریخ نشر
    2013-10-01
    1392-07-09
    ناشر
    Iranian Society of Pathology Farname Inc.
    سازمان پدید آورنده
    Dept. of Pathology Pratima Institute Medical Sciences, Karimnagar, A.P , India
    Dept. of Pathology, BLDE University's Shri BM Patil Medical College, Bijapur , Karimnagar, India
    Dept. of Pathology, BLDE University's Shri BM Patil Medical College, Bijapur , Karimnagar, India
    Dept. of Pathology, BLDE University's Shri BM Patil Medical College, Bijapur , Karimnagar, India
    Dept. of Pathology, BLDE University's Shri BM Patil Medical College, Bijapur , Karimnagar, India
    Dept. of Pathology, BLDE University's Shri BM Patil Medical College, Bijapur , Karimnagar, India

    شاپا
    1735-5303
    2345-3656
    URI
    http://ijp.iranpath.org/article_8247.html
    https://iranjournals.nlai.ir/handle/123456789/319290

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب