نمایش مختصر رکورد

dc.contributor.authorJouyban, Abolghasemen_US
dc.contributor.authorShaghaghi, Masoomehen_US
dc.contributor.authorL. Manzoori, Jamshiden_US
dc.contributor.authorsoleymani, Jafaren_US
dc.contributor.authorVaez-Gharamaleki, Jalilen_US
dc.date.accessioned1399-07-09T06:58:39Zfa_IR
dc.date.accessioned2020-09-30T06:58:39Z
dc.date.available1399-07-09T06:58:39Zfa_IR
dc.date.available2020-09-30T06:58:39Z
dc.date.issued2011-12-01en_US
dc.date.issued1390-09-10fa_IR
dc.date.submitted2011-09-14en_US
dc.date.submitted1390-06-23fa_IR
dc.identifier.citationJouyban, Abolghasem, Shaghaghi, Masoomeh, L. Manzoori, Jamshid, soleymani, Jafar, Vaez-Gharamaleki, Jalil. (2011). Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method. Iranian Journal of Pharmaceutical Research, 10(4), 695-704. doi: 10.22037/ijpr.2011.990en_US
dc.identifier.issn1735-0328
dc.identifier.issn1726-6890
dc.identifier.urihttps://dx.doi.org/10.22037/ijpr.2011.990
dc.identifier.urihttp://ijpr.sbmu.ac.ir/article_990.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/313122
dc.description.abstractA new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris-HCl buffer solution with a pH of 7.0. The effects of pH, time, order of addition of the reagents, temperature and the concentrations of Tb3+, buffer and 1,10-phenanthroline were investigated and optimized. The obtained linear range for the determination of MTX was 0.02-10 μg/mL. The detection limits (signal: noise = 3) was 0.015 μg/mL and the relative standard deviation for replicated determinations of 1 μg/mL of MTX was 1.9%. The proposed method is a simple, practical and relatively free from interference effects and was successfully applied to assess MTX in urine, serum and samples of an injection solution.en_US
dc.format.extent660
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherSchool of Pharmacy, Shahid Beheshti University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Pharmaceutical Researchen_US
dc.relation.isversionofhttps://dx.doi.org/10.22037/ijpr.2011.990
dc.subjectTerbium-Sensitizeden_US
dc.subject1,10-Phenanthrolineen_US
dc.subjectMethotrexateen_US
dc.subjectInjection solutionen_US
dc.subjectUrineen_US
dc.subjectSerumen_US
dc.titleDetermination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Methoden_US
dc.typeTexten_US
dc.typeResearch articleen_US
dc.contributor.departmentPharmaceutical Analysis Laboratory, Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.en_US
dc.contributor.departmentDepartment of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.en_US
dc.contributor.departmentDepartment of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.en_US
dc.contributor.departmentKimia Research Institute, Tabriz, Iran.en_US
dc.contributor.departmentHematology-Oncology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.en_US
dc.citation.volume10
dc.citation.issue4
dc.citation.spage695
dc.citation.epage704
nlai.contributor.orcid0000-0002-4670-2783


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد