• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Research
      • Volume 8, Number 3
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Research
      • Volume 8, Number 3
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

      (ندگان)پدیدآور
      Sorouraddin, MHFooladi, ENaseri, ARashidi, MR
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      587.7کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase activity, using phenanthridine as the substrate, has been developed and validated. Phenanthridine and phenanthridinone binary mixtures were prepared in a dynamic linear range of 0.025-1 µM and the emission flourimetric spectra of the solutions recorded at the excitation and emission wavelengths of 236 and 320-450 nm, respectively. The optimized calibration model of partial least squares (PLS) method was applied for the simultaneous determination of the concentration of each chemical in the prediction set. The limits of detection for phenanthridine and phenanthridinone were found to be 2.13 ± 0.33 and 3.41 ± 0.34 nM (mean ± SD, n = 5), respectively. This method was then used for kinetic study of phenanthridine oxidation using guinea pig and rat hepatic aldehyde oxidase. The results were compared with those obtained from a univariate spectroscopic method. Using this new spectrofluorimetric-multivariate calibration method, the Km value for the oxidation of phenanthridine with guinea pig and rat liver aldehyde oxidase were obtained as 0.83 ± 0.08 and 2.20 ± 0.40, µM (mean ± SD, n = 3), respectively.
      کلید واژگان
      Spectrofluorometry
      Partial least square
      Kinetic constant
      Aldehyde oxidase
      Phenanthridine

      شماره نشریه
      3
      تاریخ نشر
      2009-07-01
      1388-04-10
      ناشر
      School of Pharmacy, Shahid Beheshti University of Medical Sciences

      شاپا
      1735-0328
      1726-6890
      URI
      https://dx.doi.org/10.22037/ijpr.2010.807
      http://ijpr.sbmu.ac.ir/article_807.html
      https://iranjournals.nlai.ir/handle/123456789/312439

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب