      Optimization and increase production and efficiency of gas turbines GE-F9 using Media evaporative cooler in Fars combined cycle power plant

      (ندگان)پدیدآور
      Ghanaatpisheh, MohammadPakaein, Mehdi
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      809.7کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Gas turbines play an important role in supplying power for the country especially in peak electricity load. The main disadvantages are the turbines, they produce large changes are a result of climate change. However, in times of peak electricity grid and at the same time warm months, can produce gas turbines under the effect of ambient temperature, the amount of reduced considerably. The methods adopted for the turbine compressor inlet air cooling and recovery of their power optimization is necessary. In this paper, different methods of cooling the inlet air to gas turbines for Fars power plants weather conditions and eventually introduced various schemes to install combined cycle gas turbine inlet air cooling system of the plant, good design, Media evaporative air cooler system have been selected according to technical and economic evaluation. Media evaporative air cooler by an external contractor blueprint designed, constructed and installed in the plant. Performance tests are conducted at the site, 11 MW equivalent to 14.5 percent for gas units and 1.2 MW (6.2%) for steam combined cycle unit to the circuit after the Media cooling system in the summer show.
      کلید واژگان
      Increased power
      gas turbine
      Inlet air cooling
      evaporative cooling
      Media systym

      شماره نشریه
      04
      تاریخ نشر
      2015-12-01
      1394-09-10
      ناشر
      Islamic Azad University,Central Tehran Branch
      سازمان پدید آورنده
      Fars Power Generation Management ,Shiraz, Iran
      Fars Power Generation Management ,Shiraz, Iran

      شاپا
      2251-9246
      2345-6221
      URI
      http://ijsee.iauctb.ac.ir/article_519893.html
      https://iranjournals.nlai.ir/handle/123456789/308641

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب