      Optimal Short-Term Scheduling of Multi-Chiller Plants Considering Energy Requirement of Cooling Towers, Pumps and Chillers

      (ندگان)پدیدآور
      Jabari, FarkhondehMohammadi, BehnamBannae Sharifian, M.R.Ghaebi, Hadi
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      453.2کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      During extremely hot summer days, air conditioning systems are known as major electricity consumers in residential, commercial and industrial sectors. Moreover, high energy requirement of multiple-chiller plants may cause an interconnected power grid be faced with annual on-peak electrical demand, load-generation mismatch, voltage collapse and catastrophic wide area blackout. Therefore, this paper presents a day-ahead economic dispatch model for water cooled multiple chiller systems aiming to minimize total power consumption of cooling towers, pumps and chillers. In addition, refrigeration capacity limit of each chiller and cooling load-generation balance criterion are considered as optimization constraints. On/off status and partial load ratio of each chiller, power consumption of pump/cooling tower/chiller, temperature of chiller outlet water, temperature of cooling tower outlet water, mass flow rate of cooled water, mass flow rate of water flowing in and out of cooling tower are considered as decision variables. Simulations are conducted on a benchmark system with two 550 refrigeration ton (RT) units, four 1000 RT chillers and different cooling load levels over a 24-hour time horizon using generalized algebraic mathematical modeling system (GAMS) software.
      کلید واژگان
      Cooling tower
      energy consumption
      Economic dispatch
      Multi-chiller plant
      pump
      Water cooled chiller

      شماره نشریه
      03
      تاریخ نشر
      2018-09-01
      1397-06-10
      ناشر
      Islamic Azad University,Central Tehran Branch
      سازمان پدید آورنده
      Faculty of Electrical and Computer Engineering, University of Tabriz ,Tabriz, Iran, f.jabari@tabrizu.ac.ir
      Faculty of Electrical and Computer Engineering, University of Tabriz ,Tabriz, Iran
      Faculty of Electrical and Computer Engineering, University of Tabriz ,Tabriz, Iran
      Department of Mechanical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran

      شاپا
      2251-9246
      2345-6221
      URI
      http://ijsee.iauctb.ac.ir/article_664105.html
      https://iranjournals.nlai.ir/handle/123456789/308567

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب