• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Nuclear Medicine
    • Volume 13, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Nuclear Medicine
    • Volume 13, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

    (ندگان)پدیدآور
    Zakavi, Seyed RasoulHajizadeh, MohsenZonoozi, AminMomennezhad, MehdiAryana, KamranDabbagh Kakhki, Vahid Reza
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    266.3کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This study is a preliminary evaluation of motion artifacts in different reconstruction methods. Materials and Methods: Normal myocardial perfusion SPECT from a patient with low risk of CAD and no motion during imaging according to the review of cinematic images by 3 nuclear medicine specialists is selected. The scan was acquired one hour after IV injection of 740MBq of Tc-99m-MIBI through 180 degrees from RAO 45 to LPO 45, in 32 frames and 30 seconds per frame. The original images were moved artificially in frames 7, 16 and 24 (as initial, mid and late portion of imaging) from 1 to 3 pixels and for 30-90 seconds using VISION software. Also this artificial motion was applied in X and Y axis and in negative and positive directions. One hundred forty four images were produced and all were reconstructed using filtered back projection (FBP) and iterative (OSEM) reconstructions and interpreted visually and semi-quantitatively (using 17 segment model with 5 point scoring). Results: Applying one, two and three pixels motion converted normal scan to abnormal image in 2.8%, 25% and 39.6% respectively using FBP and in 18.8% , 43.2% and 68.8% respectively using OSEM reconstruction.(P
    کلید واژگان
    Myocardial perfusion SPECT
    Patient motion
    OSEM reconstruction
    FBP reconstruction
    Medical Physics, Dosimetry, Instrumentation and Radiobiology

    شماره نشریه
    1
    تاریخ نشر
    2005-01-01
    1383-10-12
    ناشر
    Research Center for Nuclear Medicine (Tehran University of Medical Sciences)
    سازمان پدید آورنده
    Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
    Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
    Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
    Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
    Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
    Department of Nuclear Medicine, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    1681-2824
    2008-2509
    URI
    http://irjnm.tums.ac.ir/article_457.html
    https://iranjournals.nlai.ir/handle/123456789/300168

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب