      چکیده
      There are fewer problems encountered with optical voltage transducers in comparison with their inductive and capacitive counterparts. Although capacitive and inductive transformers are used vastly for the purpose of measurement and protection in the networks, they cause problems such as core saturation and improper transient responses which decrease the accuracy of measurement and eficiency of the protection schemes. As a result, optical voltage transducers are considered as proper candidates for replacing the conventional inductive and capacitive transformers. Lighter weight, smaller size, larger dynamic range, wider bandwidth, insensitivity to electromagnetic interference, stability over temperature change, absence of iron core saturation, low maintenance and replacement cost, etc. are some of the advantages of optical voltage transducers over inductive and capacitive transformers. In this paper, the Modified Adaptive Method is introduced in order to measure the integral of electric field with minimum number of sensors. Using this algorithm makes the effects of other fields minimum. One more advantage of this method is the possibility of improving the accuracy of the measurement by using a correction factor. The correction factor is determined by considering the level of accuracy, environmental conditions and the number of sensors. Simulation results show the great validity and effectiveness of this method over a wide range of variations.
      کلید واژگان
      Optical Voltage Transducer
      Electric Field
      Correction Factor
      Modified Adaptive Method

      شماره نشریه
      7
      تاریخ نشر
      2009-01-01
      1387-10-12
      ناشر
      University of Tehran

      شاپا
      2476-2776
      2476-2784
      URI
      https://jac.ut.ac.ir/article_7811.html
      https://iranjournals.nlai.ir/handle/123456789/296255

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب