• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Advances in Environmental Health Research
      • Volume 4, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Advances in Environmental Health Research
      • Volume 4, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Comparison of technical and economic efficiency of extended aeration and sequencing batch reactors processes in hospital wastewater treatment

      (ندگان)پدیدآور
      Heidari, ArezooSadeghi, MahdiBay, AbotalebKeihanpour, JalalOmidi, ElhamBay, KhadijehTbatabaei, Mahmoud
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      591.1کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Wastewater of hospitals can cause many risks to public health due to having a variety of pathogenic microorganisms, pharmaceutical substances, and other hazardous toxic substances. The aim of this study was to evaluate the chemical quality of effluents from wastewater treatment plant of Falsafi Hospital and Hakim Jorjani Hospital in Gorgan, Iran, and to compare them technically and economically. This descriptive-analytical study was performed on 64 samples of raw wastewater entrance and output effluent obtained from treatment plants using extended aeration process and sequencing batch reactors (SBR) in two hospitals in Gorgan. All experiments for determination of pH, free residual chlorine, biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total suspended solids (TSS) were performed using standard methods. Finally, the obtained data were analyzed using t-test and Mann-Whitney test in SPSS software. Based on the results, the removal efficiency of BOD, COD, and TSS of the extended aeration system was 91, 90.8, and 95.7 percent, respectively, while these values for the SBR system were found to be 91.7, 91.9, and 95.3 Percent, respectively. Moreover, in the output of the two hospitals, pH values were recorded as 6.69 ± 0.26 and 7.33 ± 0.2 and the average amount of free residual chlorine was 0.12 and 0.13 mg/l, respectively. This study demonstrates good performances of the extended aeration activated sludge system and the SBR system in terms of reduction of pollution load to its standard limits for agriculture and irrigation purposes. However, due to slightly better efficiency, lower cost of investment, and operation compared to other methods, the SBR system is recommended.
      کلید واژگان
      hospital wastewater
      Extended Aeration
      Sequencing Batch Reactor
      Iran

      شماره نشریه
      1
      تاریخ نشر
      2016-01-01
      1394-10-11
      ناشر
      Kurdistan University of Medical Sciences
      سازمان پدید آورنده
      Health Center of Gorgan, Gorgan, Iran
      Department of Environmental Health Engineering, Environmental Health Research Center, School of Health AND Cereal Health Research Center, Golestan University of Medical Sciences, Gorgan, Iran
      Environmental Health Research Center, Golstan University of Medical Sciences, Gorgan, Iran
      Hakim Jorjani Hospital, Gorgan, Iran
      Manager of Falsafi Hospital, Gorgan, Iran
      Health Center of Aq Qala, Golestan, Iran
      Pazhab Tadbir Consulting Engineers, Gorgan, Iran

      شاپا
      2676-3478
      2345-3990
      URI
      https://dx.doi.org/10.22102/jaehr.2016.40220
      http://jaehr.muk.ac.ir/article_40220.html
      https://iranjournals.nlai.ir/handle/123456789/294302

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب