• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Science and Technology (Sciences)
      • Volume 32, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Science and Technology (Sciences)
      • Volume 32, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      DOSIMETRIC EVALUATION OF A NEWLY DEVELOPED RADIOCHROMIC FILM FOR RADIATION PROCESSING

      (ندگان)پدیدآور
      AKHAVAN, A.SOHRABPOUR, M.SHARIFZADEH, M.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      90.61کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Regular Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      In order to improve the performance of a newly developed radiochromic film, GIC-79, somedosimetric characteristics of this film have been studied based on relevant standard practice. The presentstudy describes some parameters that may affect the dosimeter response before, during, and after irradiation. The effect of absorbed dose rate on dosimeter response was determined by irradiating dosimeters at low absorbed dose rates with gamma rays. Calibration irradiations of dosimeters were performed with both gamma rays and also electrons to determine the effect of large difference absorbed dose rates on dosimeter response. In addition, post irradiation stability was obtained and also the temperature and humidity effects on the dosimeter response during the storage time prior to irradiation and post irradiation have been investigated
      کلید واژگان
      Dosimetry
      film dosimeter
      radiochromic film
      gamma radiation
      electron beam

      شماره نشریه
      4
      تاریخ نشر
      2008-12-01
      1387-09-11
      ناشر
      Springer
      سازمان پدید آورنده
      Radiation Applications Research School, Nuclear Science and Technology Research Institute, P.O. Box 11365-3486 Tehran, I. R. of Iran
      Department of Energy Engineering, Sharif University of Technology, Tehran, I. R. of Iran
      Radiation Applications Research School, Nuclear Science and Technology Research Institute, P.O. Box 11365-3486 Tehran, I. R. of Iran

      شاپا
      1028-6276
      URI
      https://dx.doi.org/10.22099/ijsts.2008.2297
      http://ijsts.shirazu.ac.ir/article_2297.html
      https://iranjournals.nlai.ir/handle/123456789/28565

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب