• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Cardio-Thoracic Medicine
    • Volume 4, Issue 3
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Cardio-Thoracic Medicine
    • Volume 4, Issue 3
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

    (ندگان)پدیدآور
    Mishra, PrashantSeth, HarshKhandekar, JayantMohapatra, ChandanAmmannaya, GaneshRaut, ChaitanyaSaini, JaskaranShah, Vaibhav
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    859.2کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. Materials and Methods: Between 1988 and 2008, 300 patients of rheumatic heart disease underwent double (Mitral and Aortic) valve replacement with Starr Edwards valve or St Jude mechanical valve prosthesis were implanted. These patients were studied retrospectively for preoperative data and postoperative outcome including causes of early and late deaths and the data was analyzed statistically. Results: The 30-day hospital death rate was 11.3% andlate death occurred in 11.6%. Anticoagulant regimen was followed to maintain the target pro-thrombin time at 1.5 times the control value. The actuarial survival (exclusive of hospital mortality) was 92.4%, 84.6%, and 84.4%, per year at 5, 10, and 20 years, respectively Conclusions: In view of the acknowledged advantageof superior durability, increased thromboresistance in our patient population, and its cost effectiveness the Starr-Edwards ball valve or St. Jude valve is the mechanical prosthesis of choice for advanced combined valvular disease. The low-intensity anticoagulant regimen has offered suffcient protection against thromboembolism as well as hemorrhage.
    کلید واژگان
    Double Valve Replacement
    Rheumatic Heart Disease
    Starr Edwards Valve
    St. Jude Valve

    شماره نشریه
    3
    تاریخ نشر
    2016-09-01
    1395-06-11
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Cardiovascular and Thoracic Surgeon, Department of CVTS, LTMMC and GH, Sion, Mumbai, India
    Resident of Cardiovascular and Thoracic Surgeon, Department of CVTS, LTMMC and GH, Sion, Mumbai, India.
    Cardiovascular and Thoracic Surgeon, Department of CVTS, LTMMC and GH, Sion, Mumbai, India.
    Resident of Cardiovascular and Thoracic Surgeon, Department of CVTS, LTMMC and GH, Sion, Mumbai, India
    Resident of Cardiovascular and Thoracic Surgeon, Department of CVTS, LTMMC and GH, Sion, Mumbai, India
    Cardiovascular And Thoracic Surgeon, Department Of CVTS, LTMMC And GH, Sion, Mumbai, India.
    Resident of Cardiovascular and Thoracic Surgeon, Department of CVTS, LTMMC and GH, Sion, Mumbai, India
    Resident of Cardiovascular and Thoracic Surgeon, Department of CVTS, LTMMC and GH, Sion, Mumbai, India

    شاپا
    2345-2447
    2322-5750
    URI
    https://dx.doi.org/10.22038/jctm.2016.7427
    http://jctm.mums.ac.ir/article_7427.html
    https://iranjournals.nlai.ir/handle/123456789/280770

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب