      Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

      (ندگان)پدیدآور
      Bashizadeh Fakhar, HooriehSharifian, HashemNiknami, MahdiIranmanesh, Mahboobeh
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      443.6کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scanned 4 times by each imaging modality. Gray value of the images was evaluated in four determined regions adjacent to distal, mesial, buccal and lingual aspects of the implant as the region of interest (ROI) by two observers using image J software. Gray value differences (∆GV) between the control (fixture without abutment) and case images (fixture and each type of abutments) were calculated. Data evaluation was done by analysis of variance and Post Hoc tests.Results: In CBCT, ∆GV was significantly higher in zirconium-titanium images comparing with titanium abutments. (P Value In distal, mesial and buccal aspects of ROI in CT, ∆GV was higher in zirconium images comparing with titanium abutments.In MRI, ∆GV for zirconium were lower than titanium-zirconium and titanium samples, respectively. Also, no significant differences in ∆GV were seen between T1 and T2 protocols, for all samples. Conclusion: In MRI, image artifacts are the least around Zirconium abutments, while in CT and CBCT, titanium abutments produced the least amount of artifacts.
      کلید واژگان
      Artifact
      Implant
      Titanium
      Titanium-zirconium
      Zirconium
      CBCT
      MRI
      Oral and Maxsilofacial Radiology

      شماره نشریه
      1
      تاریخ نشر
      2020-03-01
      1398-12-11
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Department of Dentomaxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences
      Tehran university of medical sciences
      Department of Maxillofacial Radiolgy, Faculty of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
      Rafsanjan dental school

      شاپا
      2322-4150
      2252-0317
      URI
      https://dx.doi.org/10.22038/jdmt.2020.44020.1317
      http://jdmt.mums.ac.ir/article_14635.html
      https://iranjournals.nlai.ir/handle/123456789/280076

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب