      Evaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements

      (ندگان)پدیدآور
      Khoshhal, MasoumehVafaee, FariborzRaisi, Sahar
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      409.3کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the borders of cancellous and cortical bone in each section of the CT images were attained by Photoshop software. Then, modeling softwares SolidWorks and NUMBER were applied to make the final three-dimensional model of jaw. Finally, the amount of stress on the surface of bone/implant was studied by means of stress analysis software (Ansys v11.0). Results: Protrusive movements of implants B and D in OD-1 showed the highest amount of strain, 2435 εµ. Also, high amounts of strain, 1668 and 1557 εµwere observed in OD-1 and OD-2 designs in lateral movements respectively. Conclusion: The bottom line is that no forces to the extent of destruction based on the Ferost model were found for these designs. The highest amount of strain occurred in OD-1 design, which is held in mild overload window. Moreover, the amounts of strain in the rest of designs investigated were in adaptive window.
      کلید واژگان
      dental implant
      stress distribution
      overdenture
      Frost model
      Dentistry
      Periodontics
      Prosthodontics

      شماره نشریه
      1
      تاریخ نشر
      2016-03-01
      1394-12-11
      ناشر
      Mashhad University of Medical Sciences
      سازمان پدید آورنده
      Assistant Professor, Department of Periodontics, Dental Research Center, Hamadan University of Medical Science, Hamadan, Iran
      Assistant Professor, Department of Prosthodontics, Dental Research Center, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.
      Resident of Prosthodontics, Department of Prosthodontics, Dental Research Center Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.

      شاپا
      2322-4150
      2252-0317
      URI
      https://dx.doi.org/10.22038/jdmt.2015.6245
      http://jdmt.mums.ac.ir/article_6245.html
      https://iranjournals.nlai.ir/handle/123456789/280044

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب