    Optimization of Body Composition Analyzer Facility, Considering Operator Dosimetry

    (ندگان)پدیدآور
    Rezaei Moghaddam, Y.Miri Hakimabadi, H.Raf’at Motavalli, L.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    2.142 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Changes in body composition may be used for monitoring progression/ regression of a disease. Prompt γ-rays in vivo neutron activation analysis (IVNAA) has been widely used for the measurement of body composition in recent years.Objective: In this paper, we tried to improve the safety of IVNAA operator.Methods: The most important factor for reducing the operator receiving dose is the optimization of shields. An appropriate shield should not only reduce the operator receiving dose, but it also must have the least effect on the detected spectrum. Because all parts of setup, including the operator shield, can be activated, the emitted γ-rays may be counted in detectors and increase the background level. In this research, several shields have been considered for an IVNAA setup. 4 different shieldsâ€"concrete, epoxy colemanite resin, paraffin borated with bismuth layer (PE-Bi layer), and paraffin borated uniformly mixed with bismuth (PE-Bi)â€"were simulated by MCNPX code.Results: We found that the PE-Bi shield decreases the absorbed dose to 77% compared with “no shield†and 74% compared to concrete. Also, the reduction rate of dose equivalent was 95% compared to “no shield†and 91% compared to colemanite resin. The neutron flux decreased almost 400 times in the presence of PE-Bi; it had less background in γ-spectrum compared to other suggested shields.Conclusion: Among the tested shields, PE-Bi would be the best one.
    کلید واژگان
    Operator shield
    Absorbed Dose
    Dose Equivalent

    شماره نشریه
    4
    تاریخ نشر
    2012-12-01
    1391-09-11
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    MSc, Physics Department of nuclear physics, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran
    Professor of nuclear physics, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran
    Assistant Professor of nuclear physics, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran

    شاپا
    2251-7200
    URI
    https://jbpe.sums.ac.ir/article_43132.html
    https://iranjournals.nlai.ir/handle/123456789/26586

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب