      A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

      (ندگان)پدیدآور
      Parande, SEsmaili Torshabi, A
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      744.8کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DIR-lab group were utilized. Four implemented registration algorithms as 1) Original Horn-Schunck, 2) Inverse consistent Horn-Schunck, 3) Original Demons and 4) Fast Demons were implemented by means of DIRART software packages. Then, the calculated vector fields are processed to reconstruct 4DCT images at any desired time using optical flow based on interpolation method. As a comparative study, the accuracy of interpolated image obtained by each strategy is measured by calculating mean square error between the interpolated image and real middle image as ground truth dataset.Results: Final results represent the ability to accomplish image interpolation among given two-paired images. Among them, Inverse Consistent Horn-Schunck algorithm has the best performance to reconstruct interpolated image with the highest accuracy while Demons method had the worst performance.Conclusion: Since image interpolation is affected by increasing the distance between two given available images, the performance accuracy of four different registration algorithms is investigated concerning this issue. As a result, Inverse Consistent Horn-Schunck does not essentially have the best performance especially in facing large displacements happened due to distance increment.
      کلید واژگان
      Four-Dimensional Computed Tomography
      Radiotherapy, Image-Guided
      Image Processing, Computer-Assisted
      Respiratory motion
      Deformable Image Registration

      شماره نشریه
      5
      تاریخ نشر
      2019-10-01
      1398-07-09
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      MSc, Faculty of Sciences and Modern Technologies Graduate University of Advanced Technology Haftbagh St. Kerman Iran
      PhD, Faculty of Sciences and Modern Technologies Graduate University of Advanced Technology Haftbagh St. Kerman Iran

      شاپا
      2251-7200
      URI
      https://dx.doi.org/10.31661/jbpe.v0i0.377
      https://jbpe.sums.ac.ir/article_44583.html
      https://iranjournals.nlai.ir/handle/123456789/26537

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب