• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Biomedical Physics and Engineering
      • Volume 9, Issue 5
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Biomedical Physics and Engineering
      • Volume 9, Issue 5
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm

      (ندگان)پدیدآور
      Hashemi, S MBahreyni, M HMohammadi, MNasseri, SBayani, SGholamhosseinian, HSalek, RShahedi, FMomennezhad, M
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      817.0کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the EPID off-axis pixel response was measured, and the grey-scale image of the EPID was converted into portal dose image using the calibration curve. Next, the scattering contribution was calculated to obtain the primary dose. Then, by means of a verified back-projection algorithm and the Scatter-to-Primary dose ratio, a 2D dose distribution at the mid-plane was obtained. Results: The results obtained from comparing the transmitted EPID dosimetry to the calculated dose, using commercial treatment planning system with gamma function while there is 3% dose difference and 3mm distance to agreement criteria, were in a good agreement. In addition, the pass rates of γ Conclusion: Based on the results, the method proposed can be used in EPID dosimetry.
      کلید واژگان
      Radiotherapy Planning, Computer-Assisted
      Dose-Response Relationship
      Radiotherapy
      Algorithms

      شماره نشریه
      5
      تاریخ نشر
      2019-10-01
      1398-07-09
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      PhD, Medical Physics Research Center, Mashhad University of medical Science, Mashhad, Iran
      PhD, Medical Physics Research Center, Mashhad University of medical Science, Mashhad, Iran
      PhD, Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA 5000, Australia
      PhD, Medical Physics Research Center, Mashhad University of medical Science, Mashhad, Iran
      MSc, Medical Physics Research Center, Mashhad University of medical Science, Mashhad, Iran
      PhD, Medical Physics Research Center, Mashhad University of medical Science, Mashhad, Iran
      MD, Cancer Research Center, Mashhad University of medical Science, Mashhad, Iran
      MSc, Department of Radiology, School of Paramedical Sciences, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran
      PhD, Medical Physics Research Center, Mashhad University of medical Science, Mashhad, Iran

      شاپا
      2251-7200
      URI
      https://dx.doi.org/10.31661/jbpe.v0i0.1082
      https://jbpe.sums.ac.ir/article_45725.html
      https://iranjournals.nlai.ir/handle/123456789/26536

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب