      Dosimetry of Occupational Radiation around Panoramic X-ray Apparatus

      (ندگان)پدیدآور
      Pakravan, A HAghamiri, S M RBamdadian, TGholami, MMoshfeghi, M
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      475.0کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background: Panoramic imaging is one of the most common imaging methods in dentistry. Regarding the side-effects of ionizing radiation, it is necessary to survey different aspects and details of panoramic imaging. In this study, we compared the absorbed x-ray dose around two panoramic x-ray units: PM 2002 CC Proline (Planmeca, Helsinki, Finland) and Cranex Tome (Soredex, Helsinki, Finland).Materials and Methods: In this cross-sectional study, 15 thermoluminescet dosemeters (TLD-100) were placed in 3 semi-circles of 40cm, 80cm and 120cm radii in order to estimate x-ray dose. Around each unit, the number of TLDs in each semi-circle was 5 with equal intervals. The center of semicircles accords with the patient's position. Each TLD was exposed 40 times. These dosemeters were read out with a Harshaw Model 4000 TLD Reader (USA). The calibration processing and the reading of dosemeters were performed by the Atomic Energy Organization of Iran.Results: The mean absorbed dose in three lines of PM 2002 CC Proline was 123.2±15.1, 118.0±11.0 and 108.0±9.1 µSv, (p=0.013). The results were 140.4±15.2, 120.2±10.4 and 111.6±11.2 µSv in Cranex Tome (p=0.208), which reveals no significant difference between two systems.Conclusion: There are no significant differences between the mean absorbed dose of surveyed models in panoramic imaging by two units (PM 2002 CC Proline and Cranex Tome). These results were less than occupational exposure recommended by ICRP, even at the highest calculated doses.
      کلید واژگان
      X-rays
      Radiation Dosage
      Radiography, Panoramic
      Occupational Exposure

      شماره نشریه
      5
      تاریخ نشر
      2019-10-01
      1398-07-09
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      MD, Department of Prosthodontics, Faculty of Dentistry, Mazandaran University of Medical Sciences, Mazandaran, Iran
      PhD, Department of Radiation Medicine, Shahid Beheshti University, Tehran, Iran
      MD, Department of Prosthesis, Faculty of Dentistry, Mazandaran University of Medical Sciences, Mazandaran, Iran
      PhD, Obesity and Eating Habits Research Center, Endocrinology and Metabolism Molecular–Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran
      MD, Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran

      شاپا
      2251-7200
      URI
      https://dx.doi.org/10.31661/jbpe.v0i0.466
      https://jbpe.sums.ac.ir/article_44605.html
      https://iranjournals.nlai.ir/handle/123456789/26533

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب