      Biological Effect of Modern Fetal Ultrasound Techniques on Human Dermal Fibroblast Cells

      (ندگان)پدیدآور
      Morshedi, MBakhshandeh, MPiryaei, AEmami, AZangeneh, MRazzaghdoust, AGhadiri, HZayeri, F
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.109 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background: Diagnostic ultrasound has been used to detect human disease especially fetus abnormalities in recent decades. Although the harmful effects of diagnostic ultrasound on human have not been established so far, several researchers showed it has had bioeffects in cell lines and in experimental animals. Three-dimensional (3D), four-dimensional (4D), and color Doppler sonography are new techniques which are widely used in diagnostic fetal ultrasonography.Objective: The study aims to evaluate some bioeffects of 3D, 4D, and color Doppler sonography in different exposure times according to the acoustic output which is set as ultrasound scanner’s default for fetal sonography in the second trimester on human dermal fibroblast (HDF) cells.Material and Methods: Exposure times selected consist of 10, 40, 70, and 100 seconds for 3D sonography, 10, 20, and 30 minutes for 4D sonography, and 10, 30, and 50 seconds for color Doppler. Cell viability, cell proliferation, and apoptosis induction on HDF cells were assessed using MTT assay, immunocytochemistry of Ki-67, and Terminal Transferase-mediated dUTP End-labeling (TUNEL) assay, respectively.Results: Exposure of cells to 3D, 4D, and color Doppler modes led to decreased cell viability and increased proliferation rate of HDF. None of the diagnostic ultrasound modes induced cell apoptosis. .Conclusion: The results indicated that 3D, 4D, and color Doppler techniques may affect the cell viability and proliferation of HDF cells, however, have no effects on the induction of apoptosis probability. Further long-term studies with other molecular endpoints are required.
      کلید واژگان
      Diagnostic Ultrasound
      3-dimentional Ultrasound
      4-dimentional Ultrasound
      Color Doppler Ultrasound
      Human Dermal Fibroblast Cells

      شماره نشریه
      3
      تاریخ نشر
      2019-06-01
      1398-03-11
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      Department of Radiology Technology, Faculty of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
      Department of Radiology Technology, Faculty of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
      Department of Biology and Anatomical Sciences, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
      Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
      Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
      Urology and Nephrology Research Center, Student Research Committee, Shahid Beheshti University of Medical Sciences, Tehran, Iran
      Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran
      Department of biostatistics and proteomics research center, Faculty of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran

      شاپا
      2251-7200
      URI
      https://dx.doi.org/10.31661/jbpe.v0i0.1085
      https://jbpe.sums.ac.ir/article_45753.html
      https://iranjournals.nlai.ir/handle/123456789/26469

      Related items

      Showing items related by title, author, creator and subject.

      • Comparison of ultrasound along with muscle stretch with ultrasound and muscle stretch along in the treatment of myofascial trigger points 

        Shahi-Moradi, D؛ Nikiyan, Y؛ Abadiyan, SH؛ Rahighi, S؛ SHariati, M (Kerman University of Medical Sciences, 1996-09-01)
        this study was a clinical trial performed using consecutive method of samplind for 3.5 years in the physiotherapy clinic of Rafsanjan university of medocal sciences.the purpose of this research was to evaluate the effect ...

      • Predictive accuracy of intraocular lens power calculation using applanation ultrasound biometry: can we still rely on ultrasound biometry? 

        Nikandish, Malihe؛ Gholami, Atefe (Birjand, Birjand University of Medical Sciences, 2019-09-01)
        Introduction: Ultrasound biometric measurements have long been the gold standard in cataract surgery. In the course of time, optical biometry replaced ultrasonography as the standard technique for axial length measurements ...

      • Contrast-enhanced ultrasound and color doppler ultrasound as guidance for transhepatic artery chemoembolization following three-dimensional conformal radiotherapy 

        Zhang, G.؛ Jiang, Y.؛ Zhou, S.؛ He, L.؛ Chen, M.؛ Long, Z.؛ Xing, H. (Tehran, Novin Medical Radiation Institute, 2022-01-01)
        Background: To explore the application of contrast-enhanced ultrasound and color Doppler ultrasonography in the treatment of primary hepatocellular carcinoma (PHC) after Transhepatic Artery Chemoembolization (TACE). Materials ...