      The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study

      (ندگان)پدیدآور
      Talebi, A SMaleki, MHejazi, PJadidi, MGhorbani, R
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.258 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      BackgroundOne of the most significant Intensity Modulated Radiation Therapy treatment benefits is a high target to normal tissue dose ratio. To improve this advantage, an additional accessory such as a compensator is used to delivering doses. Compensator-based IMRT treatment is usually operated with an energy higher than 10 MV. Photoneutrons, which have high linear energy transfer and radiobiological effectiveness, are produced by colliding high-energy photon beams with linear accelerator structures, then they deliver the unwanted doses to patients and staff. Therefore, the neutron energy spectra should be determined in order to calculate and reduce the photoneutron risk.Objective: We have conducted a comprehensive and precise study on the influence of brass compensator thickness and field size on neutron contamination spectrum in an Elekta SL 75/25 medical linear accelerator with and without the flattening filter by Monte Carlo method.Materials and Methods: MCNPX MC Code version 2.6.0 was utilized to simulate the detailed geometry of Elekta SL 75/25 head components based on Linac’s manual. This code includes an important feature to simulate the photo-neutron interactions. Photoneutrons spectrum was calculated after the Linac output benchmarking based on tuning the primary electron beam.Results and Conclusion: Based on the Friedman and Wilcoxon nonparametric tests results (P
      کلید واژگان
      Photoneutron
      Spectrum
      MCNP
      Compensator
      Field Size

      شماره نشریه
      3
      تاریخ نشر
      2018-09-01
      1397-06-10
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      M.Sc. Graduate of Medical Physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran
      Isfahan UniM.Sc. Graduate of Medical Physics, Department of Medical Physics, Isfahan University of Medical Sciences, Isfahan, Iran versity of medical science
      Assistant Professor, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran
      Associate Professor, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran
      Professor, Head of Social Determinants of Health Research Center, Semnan University of Medical Sciences,Semnan, Iran

      شاپا
      2251-7200
      URI
      https://dx.doi.org/10.31661/jbpe.v8i3Sep.918
      https://jbpe.sums.ac.ir/article_43317.html
      https://iranjournals.nlai.ir/handle/123456789/26432

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب