• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 7, Issue 3
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 7, Issue 3
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region

    (ندگان)پدیدآور
    Sedaghatian, TMomennezhad, MRasta, S HMakhdoomi, YAbdollahian, S
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    614.3کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch. Materials and Methods: In this study, we utilized cylindrical PMMA Farmer chamber, DOSE-1 electrometer and set PMMA phantom in isocenter of gantry and the Farmer chamber on the phantom. Afterwards, the gantry rotated 10°, and attenuation was assessed. To measure build-up region, we used Markus chamber, Solid water phantom and DOSE-1 electrometer. Doing so, we set Solid water phantom on isocenter of gantry and placed Markus chamber in it, then we quantified the build-up region at 0° and 180° gantry angels and compared the obtained values.Results: Notable attenuation and build-up region variation were observed in 550 TxT treatment table. The maximum rate of attenuation was 5.95% for 6 MV photon beam, at 5×5 cm2 field size and 130° gantry angle, while the maximum variation was 7 mm for 6 MV photon beam at 10×10 cm2 field size.Conclusion: Fiber carbon caused beam attenuation and variation in the build-up region. Therefore, the application of fiber carbon is recommended for planning radiotherapy to prevent skin side effects and to decrease the risk of cancer recurrence.
    کلید واژگان
    Beam Attenuation
    Carbon Fiber
    Couch Insert
    Surface Dose
    Megavoltage Radiotherapy

    شماره نشریه
    3
    تاریخ نشر
    2017-09-01
    1396-06-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Science, Tabriz, Iran
    Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Iran
    Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
    Radiotherapy and Oncology Reza Center, Mashhad, Iran
    Radiotherapy and Oncology Reza Center, Mashhad, Iran

    شاپا
    2251-7200
    URI
    https://jbpe.sums.ac.ir/article_43273.html
    https://iranjournals.nlai.ir/handle/123456789/26427

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب