• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Biomedical Physics and Engineering
      • Volume 8, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Biomedical Physics and Engineering
      • Volume 8, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Comparison and Evaluation of Different Treatment Plans with IFRT Field and 6 and 18 MV Energies in Hodgkin’s Lymphoma Involvement Neck and Mediastinum

      (ندگان)پدیدآور
      Tavakoli, M BMaleki, MAkhavan, AHadisinia, TAbedi, IAmouheidari, A
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      595.2کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background: Radiotherapy with large mantle field is an effective technique in increasing the risk of secondary cancers among HL (Hodgkin Lymphoma) patients; therefore, it is essential to choose an effective treatment field including the least medical conditions in radiotherapy.Objective: The present study aimed to plan separate fields for neck and mediastinum using various energies, to compare dose distribution with MLC and to block field formation.Materials and Methods: In this study, 3D conformal treatments, Siemens Oncor accelerator equipped with multi-leaf collimator (MLC) were performed to create anterior-posterior fields. CT-scan data of 18 female patients with neck and mediastinal involvement was imported in TIGRT treatment planning system, and then treatment plans were introduced.Results and Conclusion: Using treatment plan 1, photon 6 MV in neck weighting 1 from interior, 0.5 from posterior, photon 18MV in mediastinum weighting 1 from interior and 0.5 from posterior, it was shown that regarding the common treatment plan used with photon 6 MV, mean dose delivered to breast, lung, esophagus and larynx reduced 6, 7, 41 and 10 percent, respectively and uniformity index improved by 10 percent. Using block compared to MLC in all treatment plans offered improved average dose in all organs under study. To protect breast and lung while using MLC and block in the first treatment plan seemed to be more appropriate; however, using blocks in comparison to MLC increased delivered mean dose in all organs under study. Using separate fields with Pb blocks, though, showed smaller increase.
      کلید واژگان
      Treatment planning
      Radiotherapy
      Hodgkin
      MLC
      3D Conformal

      شماره نشریه
      1
      تاریخ نشر
      2018-03-01
      1396-12-10
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      Professor, Department of Medical Physics and Engineering, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
      M.Sc., Department of Medical Physics and Engineering, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
      Assistant Professor, Department of Radiation-Oncology, Isfahan University of Medical Sciences, Isfahan, Iran
      Ph.D. Student, Department of Medical Physics and Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
      Ph.D. Student, Department of Medical Physics and Engineering, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
      Oncologist, Department of Radiation Oncology, Isfahan Milad Hospital, Isfahan, Iran

      شاپا
      2251-7200
      URI
      https://dx.doi.org/10.31661/jbpe.v8i1Mar.759
      https://jbpe.sums.ac.ir/article_43298.html
      https://iranjournals.nlai.ir/handle/123456789/26331

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب