      Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator

      (ندگان)پدیدآور
      Robatjazi, MTanha, KMahdavi, S RBaghani, H RMirzaei, H RMousavi, MNafissi, NAkbari, E
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.943 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at the bottom of the applicators. These phase-space files were used as an input source in DOSXYZnrc and BEAMDP codes for dose calculation and analysis of the characteristic of the electron beams in all applicators and energies.Results: The results of Monte Carlo calculations are in very close agreement with the measurements. There is a decrease in the peak of the initial spectrum when electrons come from the end of accelerator wave guide to the end of applicator. By decreasing the applicator diameter, the mean energy of electron beam decreased. Using applicators and increasing their size, X-ray contamination will increase. The percentage of X-ray contamination increases by applicator diameter. This is related to the increase of the mean energy of electron beams.Conclusion: Application of PMMA collimator leads to, although well below accepted level, the production of bremsstrahlung. The results of this study showed that special design of LIAC head accompanying by PMMA collimator system cause to produce an electron beam with an individual dosimetric characteristic making it a useful tool for intraoperative radiotherapy purposes.
      کلید واژگان
      Monte Carlo Simulation
      IORT
      Photon Contamination
      Dosimetry
      LIAC

      شماره نشریه
      1
      تاریخ نشر
      2018-03-01
      1396-12-10
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      Medical Physics and Radiological Sciences Department, Sabzevar University of Medical Sciences, Sabzevar, Iran
      Persian Gulf Nuclear Medicine Research Center, Bushehr University of Medical Sciences, Bushehr, Iran
      Medical Physics Department, Iran University of Medical Sciences, Tehran, Iran
      Physics Department, School of Sciences, Hakim Sabzevari University, Sabzevar, Iran
      Radiation Therapy Department, Shahid Beheshti University of Medical Sciences, Tehran, Iran
      Medical Physics and Radiological Sciences Department, Sabzevar University of Medical Sciences, Sabzevar, Iran
      Surgery Department, Iran University of Medical Sciences, Tehran, Iran
      Oncological Surgery Department, Shahid Beheshti University of Medical Sciences, Tehran, Iranv

      شاپا
      2251-7200
      URI
      https://jbpe.sums.ac.ir/article_43296.html
      https://iranjournals.nlai.ir/handle/123456789/26329

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب