      Evaluation of the Effect of Source Geometry on the Output of Miniature X-ray Tube for Electronic Brachytherapy through Simulation

      (ندگان)پدیدآور
      Barati, BZabihzadeh, MTahmasebi Birgani, M JChegini, NFatahiasl, JMirr, I
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      2.223 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Objective: The use of miniature X-ray source in electronic brachytherapy is on the rise so there is an urgent need to acquire more knowledge on X-ray spectrum production and distribution by a dose. The aim of this research was to investigate the influence of target thickness and geometry at the source of miniature X-ray tube on tube output.Method: Five sources were simulated based on problems each with a specific geometric structure and conditions using MCNPX code. Tallies proportional to the output were used to calculate the results for the influence of source geometry on output.Results: The results of this work include the size of the optimal thickness of 5 miniature sources, energy spectrum of the sources per 50 kev and also the axial and transverse dose of simulated sources were calculated based on these thicknesses. The miniature source geometric was affected on the output x-ray tube.Conclusion: The result of this study demonstrates that hemispherical-conical, hemispherical and truncated-conical miniature sources were determined as the most suitable tools.
      کلید واژگان
      Monte Carlo
      Electronic Brachytherapy
      Target Optimization
      Energy Spectrum
      Miniature Source

      شماره نشریه
      1
      تاریخ نشر
      2018-03-01
      1396-12-10
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
      Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
      Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
      Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
      Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
      Department of Biostatistics and Epidemiology, School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

      شاپا
      2251-7200
      URI
      https://dx.doi.org/10.31661/jbpe.v8i1Mar.697
      https://jbpe.sums.ac.ir/article_43295.html
      https://iranjournals.nlai.ir/handle/123456789/26328

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب