      Specific Indoor Environmental Quality Parameters in College Computer Classrooms

      (ندگان)پدیدآور
      Chang, F.H.Li, Y.Y.Tsai, C.Y.Yang, C.R.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      200.1کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      The indoor environmental quality parameters, including temperature, relative humidity, air velocity, particulate matter concentration, illumination level, sound level, carbon dioxide concentration and ventilation rate in two computer classrooms and one general classroom were evaluated. Analytical results reveal average carbon dioxide concentration in the three classrooms during daytime classes was 785"1681 ppm. These values exceeded the exposure limits for indoor air quality suggested by the Environmental Protection Administration of the Republic of China, Taiwan (ROCEPA). The particulate matter concentration in the general classroom was 0.087 mg/m3, which exceeded the indoor air quality exposure limit for Type-1 venues recommended by the ROCEPA. Illumination level in the two computer classrooms was 386 and 176 Lux; these values are far lower than the illumination level for school classrooms suggested by Ministry of Education, Taiwan. Indoor sound levels in the three classrooms during non-class (51.4"61.9 dB(A) and class times (61.0"73.6 dBA exceeded the limit recommended by the Ministry of Education, Japan. The ventilation rates for the three classrooms were 0.41"0.65 h-1; such low ventilation rates were likely responsible for the very high indoor carbon dioxide concentrations in the three classrooms during class periods. These analytical results indicate schools should examine the efficacy of air-conditioning equipment in classrooms, particularly computer classrooms. Schools should also pay attention to ventilation rates and sound levels. Due to the poor ventilation rates in computer classrooms, this study suggests that problems arisen from the accumulation of specific toxicants dispersed by computer equipment, such as polybrominated diphenyl ethers, need further investigations.
      کلید واژگان
      Indoor environmental quality
      Ventilation rate
      Indoor air quality

      شماره نشریه
      4
      تاریخ نشر
      2009-10-01
      1388-07-09
      ناشر
      University of Tehran/Springer
      سازمان پدید آورنده
      Department of Interior Design and Graduate Institute of Architecture and Environmental Design, Shu Te University, Kaohsiung 824, Taiwan (R.O.C.)
      Department of Interior Design and Graduate Institute of Architecture and Environmental Design, Shu Te University, Kaohsiung 824, Taiwan (R.O.C.)
      Department of Business Administration, National Formosa University, Yunlin 632, Taiwan (R.O.C.)
      Department of Environmental Resources Management, Chia Nan University of Pharmacy and Science, Tainan 717, Taiwan (R.O.C.)

      شاپا
      1735-6865
      2008-2304
      URI
      https://dx.doi.org/10.22059/ijer.2010.67
      https://ijer.ut.ac.ir/article_67.html
      https://iranjournals.nlai.ir/handle/123456789/25465

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب