نمایش مختصر رکورد

dc.contributor.authorAmran, M.B.en_US
dc.contributor.authorPanggabean, A.S.en_US
dc.contributor.authorSulaeman, A.en_US
dc.contributor.authorRusnadi, M.en_US
dc.date.accessioned1399-07-08T17:37:04Zfa_IR
dc.date.accessioned2020-09-29T17:37:04Z
dc.date.available1399-07-08T17:37:04Zfa_IR
dc.date.available2020-09-29T17:37:04Z
dc.date.issued2011-04-01en_US
dc.date.issued1390-01-12fa_IR
dc.date.submitted2011-03-02en_US
dc.date.submitted1389-12-11fa_IR
dc.identifier.citationAmran, M.B., Panggabean, A.S., Sulaeman, A., Rusnadi, M.. (2011). Preparation of a Chelating Resin and its Application as a Preconcentration System for Determination of Cadmium in River Water by Flow Injection Analysis. International Journal of Environmental Research, 5(2), 531-536. doi: 10.22059/ijer.2011.337en_US
dc.identifier.issn1735-6865
dc.identifier.issn2008-2304
dc.identifier.urihttps://dx.doi.org/10.22059/ijer.2011.337
dc.identifier.urihttps://ijer.ut.ac.ir/article_337.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/25267
dc.description.abstractA chelating resin of polystyrene divinylbenzene resin functionalized by 1-(2-pyridylazo) 2- naphtol (PSDVB-PAN) has been synthesized and its sorption properties have been investigated for preconcentration and determination of cadmium at μg/L level by flame atomic absorption spectrometry. The procedure is based on the sorption of Cd(II) ions on a minicolumn of synthesized chelating resin. The retained cadmium ions can be quickly eluted from sorbent material, with the eluent stream consisting of nitric acid solution, directly to the nebulizer burner system of the flame atomic absorption spectrometer. The sorption capacity of PSDVB-PAN was found to be 7.5 mg/g at optimum pH and the chelating resin showed rapid kinetic sorption. The sorption equilibrium of Cd(II) on synthesized chelating resin was achieved just in 15 minutes. Parameters such as the pH effect on the cadmium sorption, sample volume, the sorption capacity of resin, the cadmium desorption from the resin and the analytical characteristics of the procedure were studied for the quantitative recoveries of the analyte ions. The developed system allowed a throughput rate of 15 samples h-1 with a detection limit of 1.5 μg/L. Relative standard deviation for 5 replicated injections of 50 μg/ L was 1.8%. This procedure was applied for cadmium determination in river water samples collected from Citarum River, West Java, Indonesia.en_US
dc.format.extent150
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherUniversity of Tehran/Springeren_US
dc.relation.ispartofInternational Journal of Environmental Researchen_US
dc.relation.isversionofhttps://dx.doi.org/10.22059/ijer.2011.337
dc.subjectChelating Resinen_US
dc.subjectPANen_US
dc.subjectPre-concentrationen_US
dc.subjectCadmiumen_US
dc.subjectFlow Injection Analysisen_US
dc.titlePreparation of a Chelating Resin and its Application as a Preconcentration System for Determination of Cadmium in River Water by Flow Injection Analysisen_US
dc.typeTexten_US
dc.typeOriginal Research Paperen_US
dc.contributor.department1Analytical Chemistry Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10 Bandung - 40132, Indonesiaen_US
dc.contributor.departmentDepartment of Chemistry, University of Mulawarman, Samarinda, Indonesiaen_US
dc.contributor.department1Analytical Chemistry Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10 Bandung - 40132, Indonesiaen_US
dc.contributor.department1Analytical Chemistry Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10 Bandung - 40132, Indonesiaen_US
dc.citation.volume5
dc.citation.issue2
dc.citation.spage531
dc.citation.epage536


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد