• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Environmental Research
    • Volume 5, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Environmental Research
    • Volume 5, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Preparation of a Chelating Resin and its Application as a Preconcentration System for Determination of Cadmium in River Water by Flow Injection Analysis

    (ندگان)پدیدآور
    Amran, M.B.Panggabean, A.S.Sulaeman, A.Rusnadi, M.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    150.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    A chelating resin of polystyrene divinylbenzene resin functionalized by 1-(2-pyridylazo) 2- naphtol (PSDVB-PAN) has been synthesized and its sorption properties have been investigated for preconcentration and determination of cadmium at μg/L level by flame atomic absorption spectrometry. The procedure is based on the sorption of Cd(II) ions on a minicolumn of synthesized chelating resin. The retained cadmium ions can be quickly eluted from sorbent material, with the eluent stream consisting of nitric acid solution, directly to the nebulizer burner system of the flame atomic absorption spectrometer. The sorption capacity of PSDVB-PAN was found to be 7.5 mg/g at optimum pH and the chelating resin showed rapid kinetic sorption. The sorption equilibrium of Cd(II) on synthesized chelating resin was achieved just in 15 minutes. Parameters such as the pH effect on the cadmium sorption, sample volume, the sorption capacity of resin, the cadmium desorption from the resin and the analytical characteristics of the procedure were studied for the quantitative recoveries of the analyte ions. The developed system allowed a throughput rate of 15 samples h-1 with a detection limit of 1.5 μg/L. Relative standard deviation for 5 replicated injections of 50 μg/ L was 1.8%. This procedure was applied for cadmium determination in river water samples collected from Citarum River, West Java, Indonesia.
    کلید واژگان
    Chelating Resin
    PAN
    Pre-concentration
    Cadmium
    Flow Injection Analysis

    شماره نشریه
    2
    تاریخ نشر
    2011-04-01
    1390-01-12
    ناشر
    University of Tehran/Springer
    سازمان پدید آورنده
    1Analytical Chemistry Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10 Bandung - 40132, Indonesia
    Department of Chemistry, University of Mulawarman, Samarinda, Indonesia
    1Analytical Chemistry Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10 Bandung - 40132, Indonesia
    1Analytical Chemistry Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10 Bandung - 40132, Indonesia

    شاپا
    1735-6865
    2008-2304
    URI
    https://dx.doi.org/10.22059/ijer.2011.337
    https://ijer.ut.ac.ir/article_337.html
    https://iranjournals.nlai.ir/handle/123456789/25267

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب