• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Kerman University of Medical Sciences
    • Volume 22, Issue 4
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Kerman University of Medical Sciences
    • Volume 22, Issue 4
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel

    (ندگان)پدیدآور
    Masoumi, HosseinMokhtari-Dizaji, ManijehArbabi, AzimBakhshandeh, Mohsen
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    756.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiated by copper with added formaldehyde) polymer gel and megavoltage radiation energy, the dose-dependent parameters of speed of sound and broadband ultrasonic attenuation (BUA) were evaluated. Methods: MAGIC-f polymer gel was irradiated with 1.25 MeV of Cobalt-60 and received a uniform dose in the range of 0 to 60 Gy in 2 Gy steps (2% accuracy). After calibration of ultrasound system with 500 kHz frequency, the parameters of speed of sound and BUA coefficient of exposed polymer gel samples were measured. Based on the dose-response curve, the ability of the ultrasound parameters in reading the absorbed dose was investigated. To evaluate the reasonable time interval with the most sensitive reading of the ultrasound method, samples were studied 3, 24, 36, and 48 hours after irradiation. To study the temperature readings, the gel samples irradiated at 5, 15, and 25 °C were studied. Results: The relationship of variation of speed of sound and attenuation coefficient and quality index (QI) with absorbed dose 3, 24, 36, and 48 hours after irradiation of gels are shown with a fourth-order polynomial fit. The results show that ultrasonic parameters have higher sensitivity 24 hours after irradiation. The sensitivity of dose-speed of sound and attenuation curve were 50 cm/s and 0.06 dB/MHz/Gy based on each Gy in the linear range of 4-44 Gy. Ultrasonic parameters were measured in the gel samples at 5, 15, and 25 ºC after 0-60 Gy irradiation in 2 Gy steps to determine the sensitivity of the ultrasonic properties to temperature. The measurements show that readings at 25 °C have a higher sensitivity than that at 5 and 15 °C. Thus, with an increase of 20 °C, the speed of sound increased 28 and 66 m/s before irradiation and with 60 Gy absorbed dose, respectively. Moreover, the attenuation coefficient decreased 2.50 dB/MHz before irradiation and increased 2.70 dB/MHz with 60 Gy absorbed dose. Conclusion: Acoustic properties of MAGIC-f gel, determined by measurements of speed of sound and ultrasonic broadband attenuation, indicate the ability of this technique in reading of absorbed dose. Maximum sensitivity of reading time and temperature of MAGIC-f gel were 24 hours after irradiation and 25 °C, respectively
    کلید واژگان
    Polymer gel
    MAGIC-f
    Radiation dosimetry
    Speed of sound
    Attenuation coefficient

    شماره نشریه
    4
    تاریخ نشر
    2015-07-01
    1394-04-10
    ناشر
    Kerman University of Medical Sciences
    سازمان پدید آورنده
    Ph.D. Student, Department of Medical Physics, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran
    Professor, Department of Medical Physics, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran
    Professor, Department of Radiotherapy and Oncology, School of Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
    Assistant Professor, Department of Radiology Technology, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran

    شاپا
    1023-9510
    2008-2843
    URI
    http://jkmu.kmu.ac.ir/article_16090.html
    https://iranjournals.nlai.ir/handle/123456789/249387

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب