    Abutment fracture and the technique Used to Remove the fracture portion of the Abutmet: Case Report

    (ندگان)پدیدآور
    Safari, SinaEskandarizade, Alisadegh, fereshtehHoseini Ghavam, FereshtehHejazi, Maryam
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.414 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Case Report
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Abstract This clinical report presents a case of abutment fracture, due to occlusal overload, occurred with an implant-supported restoration on right mandibular first molar of a female patient. After 6 months of prosthetic reconstruction implants, the patient returned to the clinic due to the loss of implant crown. The fractured fragment of the abutment with the screw protective cotton had remained within the crown of the first molar. A periapical radiograph was taken, which revealed that the base portion of the abutment had remained within the internal hex of the fixture.  After removing the abutment screw, the base portion of the fractured abutment did not move due to the close connection and the presence of Morse taper. After applying the methods explained in previous studies, an ultrasonic tip was used counterclockwise to remove the base segment of the implant. The fractured segment of the implant was removed without destroying the implant. Various factors are responsible for the fracture of abutments, including excessive occlusal forces, implant position, implant diameter, inadequate prosthetic adjustment, prosthesis design, metal fatigue, manufacturing defects and galvanic activity. This paper explains the reasons for abutment fractures and a novel technique used to remove the fractured portion.
    کلید واژگان
    Implant
    abutment
    Retrieval
    fracture

    شماره نشریه
    2
    تاریخ نشر
    2017-03-01
    1395-12-11
    ناشر
    Kerman University of Medical Sciences
    سازمان پدید آورنده
    Assistant Professor, Department of Prosthodontics, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
    Associate professor, kerman Oral Diseases Research Center, Kerman University of Medical Sciences, Kerman, Iran
    Postgraduate Student, Department of Prosthodontics, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
    Postgraduate Student, Department of Prosthodontics, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
    Postgraduate Student, Department of Prosthodontics, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran

    شاپا
    1023-9510
    2008-2843
    URI
    http://jkmu.kmu.ac.ir/article_46789.html
    https://iranjournals.nlai.ir/handle/123456789/248905

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب