• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Dental Biomaterials
      • Volume 2, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Dental Biomaterials
      • Volume 2, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Comparison of Viscosity among Four Orthodontic Adhesive Primers in Two Different Temperatures

      (ندگان)پدیدآور
      Abdul Aziz, Azrul HAfiz
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      251.9کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article(s)
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      AbstractStatement of Problem: The viscosity of orthodontics adhesive primers is crucial for stability and correct brackets ‘position during bond up. An excessive adhesive flow during brackets seating could change the brackets’ position.Objectives: The main purpose of this study was to investigate the viscosity of four orthodontic adhesive primers in two different temperatures.Materials and Methods: Four orthodontic adhesive primers were used in this study. They include Transbond self-etching primer (SEP; 3M Unitek, USA), Transbond XT(3M Unitek, USA), Transbond moisture insensitive primer (MIP; 3M Unitek, USA), and Unite adhesive primer (3M Unitek, USA). A controlled stress rheometer (Carri-Med MKII, UK) with truncated cone and plate were used to investigate the viscosity of each orthodontic adhesive primer in two different temperatures. The orthodontic adhesive primers were tested at 25°C and 35°C for five times to calculate the means for each material during ascent and descent of the controlled stress rheometer. Statistical analysis was done with one-way ANOVA and two-sample t-test.Results: In this study, a statistically significant difference was found among viscosity of different orthodontic adhesive primers (p = 0.005). At 25°C, the Transbond XT (192.20 ± 1.21 MPa·s) was the most viscous primer and Transbond MIP (21.74 ± 1.50 MPa·s) the least viscous one. Unite adhesive primer (143.40 ± 2.17MPa·s) was the second most viscous primer followed by Transbond SEP (44.28 ± 3.09 MPa·s). The difference of the viscosity of orthodontic adhesive primers was also statistically significant when compared in two different temperatures.Conclusions: This study showed that there was a statistically significant difference among the viscosity of the four orthodontic adhesive primers. Moreover, the viscosity of orthodontic adhesive primers also changed with temperatures. This might affect the orthodontic bond up procedure during summer and winter.Keywords: Viscosity, Adhesive Primers, Orthodontic Bonding

      شماره نشریه
      4
      تاریخ نشر
      2015-11-01
      1394-08-10
      سازمان پدید آورنده
      Orthodontic Department, Islamic Sciences University of Malaysia, Kuala Lumpur, Malaysia

      URI
      http://jdb1.sums.ac.ir/article_42550.html
      https://iranjournals.nlai.ir/handle/123456789/24283

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب