    Distributed multi-agent Load Frequency Control for a Large-scale Power System Optimized by Grey Wolf Optimizer

    (ندگان)پدیدآور
    Akbarimajd, A.Olyaee, M.Shayeghi, H.Sobhani, B.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.001 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    This paper aims to design an optimal distributed multi-agent controller for load frequency control and optimal power flow purposes. The controller parameters are optimized using Grey Wolf Optimization (GWO) algorithm. The designed optimal distributed controller is employed for load frequency control in the IEEE 30-bus test system with six generators. The controller of each generator is considered as one agent. The controllers of agents are implemented in a distributed manner that is control rule of each agent depends on the agents' own state and the states of their neighbors. Three other types of controllers including centralized controller, decentralized controller, and optimal centralized controller are considered for comparison. The performances of decentralized and distributed controllers are compared with two centralized controllers. In the optimal centralized controller and optimal distributed controller, the objective function is considered to achieve the objective of load frequency control as well as minimize power generation. Simulation results using MATLAB/SIMULINK show that although there is no global information of system in the optimal distributed controller, it has suitably reduced the frequency deviation. Meanwhile the power is optimally generated in the three scenarios of load increasing, load reduction and generator outage.
    کلید واژگان
    Load frequency control (LFC)
    Distributed controller
    Optimal power flow (OPF)
    Grey wolf optimizer (GWO)
    Multi-agent systems
    Application of Automatic Control in Power System

    شماره نشریه
    2
    تاریخ نشر
    2017-12-01
    1396-09-10
    ناشر
    University of Mohaghegh Ardabili
    دانشگاه محقق اردبیلی
    سازمان پدید آورنده
    Electrical Engineering Department, University of Mohaghegh Ardabili, Ardabil, Iran
    Department of Technical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran
    Department of Technical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran
    Department of Technical Engineering, University of Mohaghegh Ardabili, Ardabil, Iran

    شاپا
    2322-4576
    2423-4567
    URI
    https://dx.doi.org/10.22098/joape.2017.2522.1220
    http://joape.uma.ac.ir/article_594.html
    https://iranjournals.nlai.ir/handle/123456789/233000