Assessment and control of VOCs emitted from gas stations in Tehran, Iran
(ندگان)پدیدآور
Eisaei, Hamid RezaAhmadi Dehrashid, Seyed ShahoKhani, Mohammad RezaHashemi, Seyed Mukhtarنوع مدرک
TextOriginal Research Paper
زبان مدرک
Englishچکیده
In this research, gasoline vapours including Benzene, Toluene, Xylene (BTX) and Total Volatile Organic Compounds (TVOCs) emitted from vent pipes of underground storage tanks (USTs) were measured at six gas stations in Tehran. Thereafter, gas station No. 29 was selected as a pilot station and equipped with a vapour control system. The vapours were measured during the summer of 2013 and winter of 2014 in two states, before and at the time of gasoline discharge from a petrol tanker to the UST. The results reveal that the average of BTX and TVOCs are 161.22, 200.81, 229 and 647.01 ppm, respectively, higher than the World Health Organisation (WHO) guidelines. The average of TVOCs and BTX in the situation in which the control system is inactive at the pilot station, are 259.13, 55.9, 73.03 and 96.88 ppm, respectively. After activating the control system at the pilot station, the VOCs were reduced by 0.01 ppm. Almost 99.99% control was obtained for this system and 87% of the people living around the pilot station were satisfied and no longer had any complaints about the bad odour of VOCs. It can be concluded that gasoline discharge from the petrol tanker to UST, is the main reason behind the overproduction of VOCs in Tehran's gas stations (P
کلید واژگان
benzenegas station
toluene
xylene
volatile organic compounds (VOCs)
شماره نشریه
4تاریخ نشر
2015-10-011394-07-09
ناشر
University of Tehranسازمان پدید آورنده
Department of Environmental Engineering, Graduate School of the Environment and Energy, Science and Research Branch, Islamic Azad University, Hesarak, P.O. Box 14515-775, Tehran, IranDepartment of Environmental Engineering, Graduate School of the Environment and Energy, Science and Research Branch, Islamic Azad University, Hesarak, P.O. Box 14515-775, Tehran, Iran
Department of Environmental Health Engineering, School of the Public Health, Tehran Branch of Medical Sciences, Islamic Azad University, Tehran, Iran
Newcastle Institute for Research on Sustainability, NIReS, School of Civil Engineering and Geosciences, University of Newcastle Upon Tyne, NE1 7RU, UK
شاپا
2383-451X2383-4501