    Comparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques

    (ندگان)پدیدآور
    Giahi, MasoudBagherinia, Mohammad AliAzari, Azin
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    564.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 10-5 to 1.0 × 10-1 mol dm-3 for sol-gel and PVC membrane sensors.The PVC-based and sol-gel electrodes show detection limits of 3.1 × 10-6 and 4.9 × 10-7 mol dm-3, respectively, and also response time of about 15 s to achieve a 95% steady potential for VO2+concentration. By testing the stability lifetimes of the electrodes over a six-month period, nosignificant change was observed in the performance of the sol-gel electrode, however, the PVCbasedvanadyl-selective electrode exhibited a gradual decrease in the slope after two months.Investigating the influence of membrane composition, the pH of the test solution, and theinterfering ions on the electrodes performance revealed good selectivity of electrodes for a numberof alkali, alkaline earth, transition and heavy metal ions. The determined isothermal temperaturecoefficients of these electrodes showed a better thermal stability of sol-gel electrode rather thanthat of the PVC-based vanadyl-selective electrode, however, the electrodes performance isdeteriorated by temperatures higher than 50 °C.
    کلید واژگان
    Vanadyl sensor
    Sol-gel process
    Thiacalix[4]arene
    Poly(vinyl chloride)
    Potentiometry

    شماره نشریه
    3
    تاریخ نشر
    2007-11-01
    1386-08-10
    ناشر
    Tehran, Islamic Azad University of Iran, Science and Research Branch
    سازمان پدید آورنده
    Not-mentioned
    Not-mentioned
    Not-mentioned

    URI
    http://jptc.srbiau.ac.ir/article_6596.html
    https://iranjournals.nlai.ir/handle/123456789/203497

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب