    Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

    (ندگان)پدیدآور
    Ahmadzadehtalatapeh, Mohammad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    293.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To this end, effectiveness-NTU approach was employed to determine the thermal performance of the heat exchanger. Water-to-air HPHEX with different numbers of rows namely two, four, and six was studied to determine the heat transfer characteristics of the heat exchanger. The thermal performance of the water-to-air HPHEX was investigated under different operating conditions in terms of evaporator inlet air and condenser inlet water coil face velocities and temperatures. After determining the thermal performance of the water-to-air HPHEX, the air pre-cooling capability of the water-to-air HPHEX was explored hour-by-hour for the required months of the year by using TRNSYS software. Based on the simulations results, the water-to-air HPHEX shows an acceptable thermal performance under the operating conditions. In addition, studies showed that the water-to-air HPHEX has a significant capability for air pre-cooling, which makes it applicable to be implemented in the air-conditioning systems operating in south of Iran.
    کلید واژگان
    Effectiveness‐NTU
    Heat Pipe based Heat Exchanger (HPHEX)
    Air Pre‐Cooling
    Thermal Performance

    شماره نشریه
    3
    تاریخ نشر
    2016-08-01
    1395-05-11
    ناشر
    Materials and Energy Research Center (MERC) Iranian Association of Chemical Engineers (IAChE)
    سازمان پدید آورنده
    Department of Marine & Mechanical Engineering, Chabahar Maritime University, Chabahar, Iran

    شاپا
    2423-5547
    2423-7469
    URI
    https://dx.doi.org/10.30501/jree.2016.70091
    http://www.jree.ir/article_70091.html
    https://iranjournals.nlai.ir/handle/123456789/201472

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب