• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Progress in Chemical and Biochemical Research
      • Volume 2, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Progress in Chemical and Biochemical Research
      • Volume 2, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Development of chemically modified pencil graphite electrode based on benzo-18-crown-6 and multi-walled CNTs for determination of lead in water samples

      (ندگان)پدیدآور
      Elobeid, Walaa HaiderElbashir, Abdalla Ahmed
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.224 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      An improvement to the performance of the bare pencil graphite electrode (PGE) was made by modifying it utilizing p-amino benzene sulfonic acid (p-ABSA), benzo-18-crown-6 and multi-walled carbon nanotubes (CNTs) to detect lead (II) ions in water samples using differential pulse anodic stripping voltammetric technique. The presence of p-ABSA serves as ionic conductor while the good adsorption ability and electrical conductivity of multi-walled CNTs enhanced the sensitivity through increasing the electrochemical active surface area. Furthermore, using benzo-18-crown-6 as a molecular scavenger improved the selectivity for lead (II) ions. After optimizing the experimental and chemical parameters, the proposed electrode demonstrated linearity toward the lead (II) ions in a concentration range of 15-200 µM, and 0.99852 correlation factor at 5 sec accumulation time. The detection and qualification limits were statistically calculated based on ICH guidelines as 5.72 µM and 17.32 µM, respectively. The sensor demonstrated a very good selectivity over heavy metals for instance Zn (II), Fe (III), Cr (III), Cu (II) and Mn (VI). The developed method was adequately applied for the determination of Pb (II) ions in water samples. The results obtained by the current method were compared to the acquired results utilizing ICP-OES. According to the statistical consideration, the two methods were considered identical.
      کلید واژگان
      Differential pulse anodic stripping voltammetry
      Carbon nanotubes
      Crown-ether, molecular scavenger

      شماره نشریه
      1
      تاریخ نشر
      2019-02-01
      1397-11-12
      ناشر
      Sami Publishing Company
      سازمان پدید آورنده
      University of Khartoum, Faculty of Science, Department of Chemistry, Khartoum, Sudan
      University of Khartoum, Faculty of Science, Department of Chemistry, Khartoum, Sudan

      شاپا
      2676-7090
      2645-6133
      URI
      https://dx.doi.org/10.33945/SAMI/PCBR.2019.2.2433
      http://www.pcbiochemres.com/article_85009.html
      https://iranjournals.nlai.ir/handle/123456789/19645

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب