      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Reduced graphene oxide based on simultaneous detection of neurotransmitters

      (ندگان)پدیدآور
      Vinodhkumar, G.Ramya, Rvimalan, markPotheher, ICyrac Peter, A.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      2.042 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Reduced graphene oxide (rGO) is synthesized using strong oxidizing agents with the help of chemical reduction method. Structural and physiochemical properties of the prepared sample are studied by ultraviolet-visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FTIR), X-ray powder diffraction (XRD) and scanning electron microscopy (SEM). UV-Vis spectra of GO exhibit maximum absorption peak attributable to restoration of sp2carbon. Electrochemical study performed for bare and rGO modified glassy carbon electrode. Electrochemical sensing of Dopamine (DA) and Uric Acid (UA) was examined by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV) were conducted in phosphate buffer solution (PBS) at pH = 7.0 done for both simultaneous and individual determination of DA and UA in the range of 500nM – 1mM exhibit a wide linear range of detection and having low limit of detection (LOD) of 0.67µM for DA, and 0.69µM for UA estimated for simultaneous determination and in individual determination it was found to be 0.51µM and 0.42µM for DA and UA respectively. Additionally, the modified electrode exhibits good reproducibility, selectivity, sensitivity and stability. The proposed sensor could be applied for the determination of DA and UA in real samples.
      کلید واژگان
      Graphene oxide (GO)
      Hummer’s method
      Cyclic Voltammetry
      Electrochemical sensor
      Dopamine
      Uric Acid

      شماره نشریه
      1
      تاریخ نشر
      2018-10-01
      1397-07-09
      ناشر
      Sami Publishing Company
      سازمان پدید آورنده
      Department of Physics, Raja Doraisingam Govt. Arts College, Sivaganga, India.
      Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi, India.
      Department of Physics, Thirumalai Engineering College, Kilambi, Kancheepuram, India
      Department of Physics, Bharathidasan Institute of Technology (BIT) Campus, Anna University, Thiruchirappalli, India.
      Department of Physics, Raja Doraisingam Govt. Arts College, Sivaganga, India.

      شاپا
      2676-7090
      2645-6133
      URI
      https://dx.doi.org/10.29088/SAMI/PCBR.2018.1.4049
      http://www.pcbiochemres.com/article_81409.html
      https://iranjournals.nlai.ir/handle/123456789/19639

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب