• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Progress in Chemical and Biochemical Research
    • Volume 1, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Progress in Chemical and Biochemical Research
    • Volume 1, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Reduced graphene oxide based on simultaneous detection of neurotransmitters

    (ندگان)پدیدآور
    Vinodhkumar, G.Ramya, Rvimalan, markPotheher, ICyrac Peter, A.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    2.042 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Reduced graphene oxide (rGO) is synthesized using strong oxidizing agents with the help of chemical reduction method. Structural and physiochemical properties of the prepared sample are studied by ultraviolet-visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FTIR), X-ray powder diffraction (XRD) and scanning electron microscopy (SEM). UV-Vis spectra of GO exhibit maximum absorption peak attributable to restoration of sp2carbon. Electrochemical study performed for bare and rGO modified glassy carbon electrode. Electrochemical sensing of Dopamine (DA) and Uric Acid (UA) was examined by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV) were conducted in phosphate buffer solution (PBS) at pH = 7.0 done for both simultaneous and individual determination of DA and UA in the range of 500nM – 1mM exhibit a wide linear range of detection and having low limit of detection (LOD) of 0.67µM for DA, and 0.69µM for UA estimated for simultaneous determination and in individual determination it was found to be 0.51µM and 0.42µM for DA and UA respectively. Additionally, the modified electrode exhibits good reproducibility, selectivity, sensitivity and stability. The proposed sensor could be applied for the determination of DA and UA in real samples.
    کلید واژگان
    Graphene oxide (GO)
    Hummer’s method
    Cyclic Voltammetry
    Electrochemical sensor
    Dopamine
    Uric Acid

    شماره نشریه
    1
    تاریخ نشر
    2018-10-01
    1397-07-09
    ناشر
    Sami Publishing Company
    سازمان پدید آورنده
    Department of Physics, Raja Doraisingam Govt. Arts College, Sivaganga, India.
    Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi, India.
    Department of Physics, Thirumalai Engineering College, Kilambi, Kancheepuram, India
    Department of Physics, Bharathidasan Institute of Technology (BIT) Campus, Anna University, Thiruchirappalli, India.
    Department of Physics, Raja Doraisingam Govt. Arts College, Sivaganga, India.

    شاپا
    2676-7090
    2645-6133
    URI
    https://dx.doi.org/10.29088/SAMI/PCBR.2018.1.4049
    http://www.pcbiochemres.com/article_81409.html
    https://iranjournals.nlai.ir/handle/123456789/19639

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب