      Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

      (ندگان)پدیدآور
      Khatri, KavinSharma, VijayFarooque, KamranTiwari, Vivek
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      15.65 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. Objectives This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. Patients and Methods We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 ± 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 ± 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley’s demerit scoring system was used to assess the final outcome. Results There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. Conclusions The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications.
      کلید واژگان
      Bone Plates
      radius
      Volar Plate
      Fracture fixation
      Internal
      Injury
      Wrist

      شماره نشریه
      2
      تاریخ نشر
      2016-05-01
      1395-02-12
      ناشر
      Kashan University of Medical Sciences
      سازمان پدید آورنده
      Department of Orthopaedics, GGS Medical College Faridkot, Baba Farid University of Health Sciences, Faridkot, India
      Department of Orthopaedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, (AIIMS), New Delhi, Delhi, India
      Department of Orthopaedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, (AIIMS), New Delhi, Delhi, India
      Department of Orthopaedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, (AIIMS), New Delhi, Delhi, India

      شاپا
      2251-953X
      2251-9599
      URI
      https://dx.doi.org/10.5812/atr.25174
      http://archtrauma.kaums.ac.ir/article_62253.html
      https://iranjournals.nlai.ir/handle/123456789/17834

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب