• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Archives of Trauma Research,
      • Volume 6, Issue 2
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Archives of Trauma Research,
      • Volume 6, Issue 2
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Diagnostic Value of Serial Ultrasound in Blunt Abdominal Trauma

      (ندگان)پدیدآور
      Davoodabadi, AbdolhosseinMarzban, FaramarzGhafoor, LeilaTalari, Hamid RezaAbdolrahim-Kashi, EsmaeilAkbari, HosseinMahdian, Mehrdad
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      97.92کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background Ultrasound has widely been used to assess patients with blunt abdominal trauma and detect free fluid in the abdomen. Nevertheless, different studies reported different false negative for this imaging technique. Objectives The present study was conducted to evaluate the diagnostic value of the repetitive ultrasound in diagnosis of free intraperitoneal fluid. Methods In this study, 125 patients with abdominal blunt trauma were recruited prospectively for ultrasound evaluation. Ultrasound and CT- scan were performed for all recruited patients in the study. In case of positive ultrasound or CT-scan (free fluid in the peritoneal cavity), patients underwent surgical operation. In the presence of negative ultrasound and CT-scan, and if the patient was alert and had stable vital signs, then, he/she would undergo exact supervision. In such patients, ultrasound and CT-scan were repeated 12 and 24 hours after admission. If any of the tests were positive, the patient underwent laparotomy. Moreover, if ultrasound and CT-scan examinations were negative 24 hours after admission, the patients with normal laboratory tests were discharged according to the surgeon's decision. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Results Of the 125 patients with abdominal blunt trauma, 90 patients finally underwent laparotomy. Based on the surgical outcome as the gold standard, the initial, 12 hours, and 24 hours sensitivity were measured to be 19.8%, 75.2%, and 82.2%, respectively. These numbers for specificity were 91.7, 75, and 70.8, respectively; they were 90.9, 92.6, and 92.2 for PPV, and 21.3, 41.8, and 48.5 for NPV, respectively. Conclusions The sensitivity of ultrasound to detect intraperitoneal fluid in blunt abdominal trauma cases will be increased by repeated ultrasound examinations.
      کلید واژگان
      Abdominal Injuries
      Ultrasonography
      Hemoperitoneum

      شماره نشریه
      2
      تاریخ نشر
      2017-04-01
      1396-01-12
      ناشر
      Kashan University of Medical Sciences
      سازمان پدید آورنده
      Department of Surgery, Kashan University of Medical Sciences, Kashan, IR Iran
      Department of Surgery, Kashan University of Medical Sciences, Kashan, IR Iran
      Department of Surgery, Kashan University of Medical Sciences, Kashan, IR Iran
      Department of Radiology, Kashan University of Medical Sciences, Kashan, IR Iran
      Department of Surgery, Kashan University of Medical Sciences, Kashan, IR Iran
      Trauma Research Center, Kashan University of Medical Sciences, Kashan, IR Iran
      Trauma Research Center, Kashan University of Medical Sciences, Kashan, IR Iran

      شاپا
      2251-953X
      2251-9599
      URI
      https://dx.doi.org/10.5812/atr.44176
      http://archtrauma.kaums.ac.ir/article_62308.html
      https://iranjournals.nlai.ir/handle/123456789/17620

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب