Evaluation of Damage Problems in the Water Pump Components of an Air Compressor Cooling System: a Case Study
(ندگان)پدیدآور
Tayebi, MoslemMoghadasi, HesamRahmatabadi, DavoodMohemi, EnayatolahHashemi, Raminنوع مدرک
TextResearch Paper
زبان مدرک
Englishچکیده
In this paper, the reasons of damage water pumps parts of the air compressor cooling system were studied. To reach this goal, the works like preparing metallographic samples, evaluation of structure, investigation of mechanical properties, the alloy parts detection and chemical analysis of deposit and corrosion products collected from the parts were performed. According to studies and results obtained, alloys suggested to be used in the impeller and casing are gray cast iron with flake graphite (random distributed) and ductile iron with spherical graphite (distributed almost uniformly), respectively. Also cause damage to the pump impeller, graphitic corrosion was described.
کلید واژگان
ImpellerCasing
Graphitic Corrosion
Gray Cast Iron
Air Compressor Cooling System
شماره نشریه
3تاریخ نشر
2016-08-011395-05-11
ناشر
Islamic Azad Univesity, Najafabad Branchسازمان پدید آورنده
School of Materials Science, Sahand University of Technology, Tabriz, IranSchool of Mechanical Engineering, Iran University of Science and Technology (IUST), Narmak, 16846-13114, Tehran, Iran
School of Mechanical Engineering, Iran University of Science and Technology (IUST), Narmak, 16846-13114, Tehran, Iran
National Iranian South Oil Company, Technical Inspection and Corrosion Metals Laboratory
School of Mechanical Engineering, Iran University of Science and Technology (IUST), Narmak, 16846-13114, Tehran, Iran
شاپا
2717-03142717-0322