    Experimental and 3D CFD investigation on energy separation inside a convergent vortex tube air separator

    (ندگان)پدیدآور
    Rafiee, Seyed EhsanSadeghiazad, M. M.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    4.189 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    The vortex tube air separator is an invaluable tool which has the ability to separate a high pressure fluid into the cold and hot fluid streams. The hot tube is a main part of the vortex tube which the energy separation procedure happens along this part. This research has been done to analyze the effect of the convergent angle and cold orifice diameter on the thermal efficiency of a convergent vortex tube. The convergent hot tubeangleis varied over the range of 1 to 9deg. The consideration of the main angle effect, denotes that the highest thermal ability could be achieved at β=5deg. Experiments denoted that both cooling capability and heating effectiveness reach the highest magnitudes when the DCold is around 9mm. After these two stages; the optimized convergent vortex tube was capable of decreasing and rising air temperatures at the cold and the hot sides up to 9.05K(42.89%) and 10.48K(44.74%) respectively. A computational fluid dynamics model was employed to predict the performance of the convergent vortex tube. The numerical investigation was done by full 3D steady state CFD-simulation using FLUENT6.3.26. The results show that the agreement between computation predictions and laboratory measurements is fairly good.
    کلید واژگان
    Experimental approach
    Numerical computation
    Convergent hot tube
    Air separator
    Convergent angle
    Cold orifice diameter

    شماره نشریه
    4
    تاریخ نشر
    2016-08-01
    1395-05-11
    ناشر
    Sharif University of Technology
    سازمان پدید آورنده
    Assistant Professor
    Associate Professor

    شاپا
    1026-3098
    2345-3605
    URI
    https://dx.doi.org/10.24200/sci.2016.3923
    http://scientiairanica.sharif.edu/article_3923.html
    https://iranjournals.nlai.ir/handle/123456789/119264

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب