• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 22, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 22, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Enhancing Fricke Xylenol Gel Dosimeter's Response to Radiation with Optimized Preparation Methods

    (ندگان)پدیدآور
    Shajid, SyedMANDAL, ABHIJITMondal, KalyanPriean V, GogulMukherjee, BratindranathPandey, Praveen ChandraMishra, HimanshuMishra, RitushaPatel, GaneshkumarMourya, AnkurAggarwal, LalitChoudhary, Sunil
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.382 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: The fundamental principle of the Fricke gel dosimeter involves the oxidation of ferric ions upon exposure to radiation. However, a significant limitation of this dosimeter is the post-irradiation diffusion of ferric ions, which can result in the degradation of spatial dose information. Material and Methods: Gels were prepared using 300 bloom gelatin, deionized water, sulfuric acid, ferrous ammonium sulfate, and xylenol orange dye (Sigma-Aldrich). The solution was then poured into 10 ml plastic cuvettes.. The gel samples were refrigerated at various temperatures for 1 to 10 days and irradiated within a water bath environment utilizing a telecobalt unit (Phoenix, Theratronics) employing parallel opposed beams. Spectrophotometric analysis at  a wavelength of 585 nm was used to measured optical density changes with dose.. This procedure was repeated across gel formulations prepared under differing pH conditions. Results: The gel's optimum pH value, which was stored for 10 days at 5° C, showed a linear response up to 10 Gy, although the storage time was longer than that of the gels with low (0.3) and high pH (1.3). The auto oxidation rate was determined and found to be less for non-irradiated gel batches stored at 5° C in relation to the gel samples at room temperature and freezing temperature. Conclusion: The dose response of the dosimeter is highly dependent on its pH, composition, alkaline residuals, and pre-irradiation storing conditions.. We observed the optimum pH is 1, at which the dosimeter shows a maximum response. Storing gel samples at 5°C notably reduces the Fe2+ to Fe3+ auto-oxidation rate.
    کلید واژگان
    Cancer
    Radiation Therapy
    Fricke Solutions
    Spectrophotometry
    Radiation Detection & Measurement

    شماره نشریه
    1
    تاریخ نشر
    2025-02-01
    1403-11-13
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University.
    BANARAS HINDU UNIVERSITY
    Department of Radiotherapy, North Bengal Medical College, Darjeeling, India-734012
    Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University
    Department of Metallurgical Engineering, Institute of Technology, Banaras Hindu University.
    Department of Physics, Institute of Technology, Banaras Hindu University
    Department of Radiotherapy and Radiation Medicine Institute of Medical Sciences Banaras Hindu University VARANASI, Uttar Pradesh, INDIA.
    RTRM Department, Institute of Medical Sciences, BHU, Varanasi-221005
    RTRM Department, Institute of Medical Sciences, Banaras Hindu University, Varanasi-221005, INDIA
    Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University.
    Institute of Medical Science (BHU)Varanasi, UP, India
    Department of Radiotherapy and Radiation Medicine Institute of Medical Sciences Banaras Hindu University VARANASI, Uttar Pradesh, INDIA.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2024.74538.2320
    https://ijmp.mums.ac.ir/article_24076.html
    https://iranjournals.nlai.ir/handle/123456789/1161279

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب