    Comparison of Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy with Brachytherapy for Carcinoma Cervix Boost

    (ندگان)پدیدآور
    DSOUZA, RECHALKalita, BanashreeChandraguthi, Srinidhirao, shreekripaSharan, Krishna
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.511 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: It is challenging to deliver brachytherapy for patients who refuse minor surgical insertion of applicators.  As external beam radiation therapy(EBRT) can be delivered more precisely using advanced radiotherapy techniques, this study compares the dosimetric differences between intensity-modulated radiation therapy(IMRT), volumetric-modulated arc therapy(VMAT), and intracavitary brachytherapy (ICBT) for cervix boost. Material and Methods: Thirty patients with cervix cancer treated with 3-dimensional conformal radiation therapy (3DCRT) followed by ICBT were considered retrospectively for this study. IMRT and VMAT plans were generated for high-risk clinical target volume (HR-CTV). The dose prescription for VMAT and IMRT plans were the same as the ICBT, between 6 to 7.5 Gy per fraction. Target coverage (TC), organ at risk(OAR) doses, conformity index(CI), homogeneity index(HI), BED(biologically effective dose), and EQD2(2Gy equivalent dose) were calculated. IMRT and VMAT were compared with ICBT. Results: The EBRT plans in comparison to ICBT gave exceptional target coverage greater than 95%.  Mean dose and D2cc to bladder and rectum in the EBRT plans were higher than ICBT. Dose to bladder, rectum and femur were high in the IMRT plans. Bowel bag dose in ICBT was higher compared to EBRT.  Target conformity was superior for ICBT compared EBRT, however homogeneity was better for the EBRT plans. EQD2 values for bladder and rectum for all three plans were well within accepted tolerances. Conclusion: The current study dosimetrically suggests that in the absence of a Brachytherapy unit or if patients are unwilling to brachytherapy, EBRT can be opted for, with VMAT being the more suitable choice of treatment.
    کلید واژگان
    Uterine Cervical Neoplasm Volumetric
    Modulated Arc Therapy Intensity
    Modulated Brachytherapy Radiotherapy
    Medical Physics

    شماره نشریه
    1
    تاریخ نشر
    2025-02-01
    1403-11-13
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    ASSISTANT PROFESSOR, MEDICAL RADIATION PHYSICS PROGRAM, MANIPAL COLLEGE OF HEALTH PROFESSIONS(MCHP), MANIPAL ACADEMY OF HIGHER EDUCATION(MAHE), MANIPAL-576104, KARNATAKA, INDIA
    Medical Radiation Physics Programme, Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India.
    Radiotherapy and Oncology Senior Grade Lecturer Medical Physics Kasturba Medical College Manipal Academy of Higher Education Manipal India
    Radiotherapy and Oncology Assistant Professor in Medical Physics School of Allied Health Sciences Kasturba Medical College Manipal Academy of Higher Education Manipal 576104
    KSHEMA, NITTE, MANGALORE

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2024.75913.2336
    https://ijmp.mums.ac.ir/article_24365.html
    https://iranjournals.nlai.ir/handle/123456789/1161276

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب