    Assessment of Dosimetric Uncertainties in Liver Stereotactic Body Radiation Therapy using kilo-voltage Cone-Beam CT

    (ندگان)پدیدآور
    C O, ClintoB, Bindhu
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.165 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Liver stereotactic body radiation therapy (SBRT) presents distinct challenges caused by respiratory and gastrointestinal motion. While deep inspiration breath hold (DIBH) reduces respiratory motion, gastrointestinal movement and variability in breath-hold consistency can lead to inaccuracies in tumor localization and sparing of critical organs. This study examines dosimetric uncertainties in liver SBRT with DIBH using kilo-voltage cone-beam computed tomography (kV-CBCT).Material and Methods: In this study, twenty-five liver stereotactic body radiation therapy (SBRT) cases were evaluated retrospectively. All patients underwent treatment with volumetric modulated arc therapy (VMAT) in five fractions. The Varian real-time position management™ (RPM) system was employed for image acquisition and delivery with a 5 mm amplitude interval. Treatment plan verifications were performed using daily CBCT at the treatment isocenter. The Varian SmartAdapt automatic deformable image registration tool was utilized for contour propagation. Different dosimetric parameters, including the planning target volume (PTV) mean dose, maximum dose to the spinal canal, liver 21 Gy sparing volume, maximum dose to luminal organs, and dose received by 10 cc, were compared. Paired t-tests were employed to evaluate significant dosimetric changes with a P-value of less than 0.05 considered statistically significant.Results: Among the 25 patients, the PTV Dmean (mean dose) decreased in all cases, with an average reduction of 2.2% (P
    کلید واژگان
    Liver SBRT Cone
    beam CT Breath hold
    Medical Physics

    شماره نشریه
    1
    تاریخ نشر
    2025-02-01
    1403-11-13
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Physics, Noorul Islam Center for Higher Education, Kumaracoil, Kanyakumari, Tamil Nadu.
    Department of Physics, Noorul Islam Centre for Higher Education, Kumaracoil, Tamil Nadu, India.

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2025.82233.2448
    https://ijmp.mums.ac.ir/article_25900.html
    https://iranjournals.nlai.ir/handle/123456789/1161275

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب