نمایش مختصر رکورد

dc.contributor.authorFrappa, Mirkoen_US
dc.contributor.authorBrunetti, Adeleen_US
dc.contributor.authorDrioli, Enricoen_US
dc.contributor.authorCui, Zhaoliangen_US
dc.contributor.authorPan, Junen_US
dc.contributor.authorMacedonio, Francescaen_US
dc.date.accessioned1399-07-08T18:30:27Zfa_IR
dc.date.accessioned2020-09-29T18:30:27Z
dc.date.available1399-07-08T18:30:27Zfa_IR
dc.date.available2020-09-29T18:30:27Z
dc.date.issued2020-01-01en_US
dc.date.issued1398-10-11fa_IR
dc.date.submitted2019-08-08en_US
dc.date.submitted1398-05-17fa_IR
dc.identifier.citationFrappa, Mirko, Brunetti, Adele, Drioli, Enrico, Cui, Zhaoliang, Pan, Jun, Macedonio, Francesca. (2020). Membrane Condenser for Particulate Abatement from Waste-Gaseous Streams. Journal of Membrane Science and Research, 6(1), 81-89. doi: 10.22079/jmsr.2019.112686.1282en_US
dc.identifier.issn2476-5406
dc.identifier.urihttps://dx.doi.org/10.22079/jmsr.2019.112686.1282
dc.identifier.urihttp://www.msrjournal.com/article_36914.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/45653
dc.description.abstractMembrane Condenser (MC) is a novel membrane contactor operation recently investigated for the valorization of industrial waste gaseous streams. In particular, until now, it was applied for water recovery from flue gas, cooling tower plumes, etc. More recently, its effectiveness and flexibility in contaminants (such as, NH3 , HF, SO2 ) removal and control from waste gaseous streams was also proved. In the present work, the application of membrane condenser for water recovery as well as microparticles removal from gaseous streams are presented. Experimental tests showed that microparticles did not affect membrane condenser performance, neither in terms of water recovery nor in term of fouling. Moreover, the carried-out tests revealed also that the complete retention of particles can be achieved only through the proper choice of the membrane, with pore size lower than particles diameter.en_US
dc.format.extent2190
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherFIMTEC & MPRLen_US
dc.relation.ispartofJournal of Membrane Science and Researchen_US
dc.relation.isversionofhttps://dx.doi.org/10.22079/jmsr.2019.112686.1282
dc.subjectmembrane condenseren_US
dc.subjectwaste gaseous streamsen_US
dc.subjectparticulate removalen_US
dc.subjectWater recoveryen_US
dc.titleMembrane Condenser for Particulate Abatement from Waste-Gaseous Streamsen_US
dc.typeTexten_US
dc.typeResearch Paperen_US
dc.contributor.departmentITM-CNR, Via P. Bucci cubo 17/C c/o Università della Calabria 87036 Rende (CS)en_US
dc.contributor.departmentITM-CNRen_US
dc.contributor.departmentIstituto per la Tecnologia delle Membrane (ITM-CNR), Italyen_US
dc.contributor.departmentState Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, Nanjing 210009, Chinaen_US
dc.contributor.departmentNanjing Tech Universityen_US
dc.contributor.departmentNational Research Council, Institute on Membrane Technology (ITM–CNR), Via Pietro BUCCI, c/o University of Calabria, Cubo 17C, 87036, Rende, CS, Italyen_US
dc.citation.volume6
dc.citation.issue1
dc.citation.spage81
dc.citation.epage89
nlai.contributor.orcid0000-0003-1092-5368
nlai.contributor.orcid0000-0002-8243-3963


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد