| dc.contributor.author | Forogh, B. | en_US |
| dc.contributor.author | Ghasemzadeh, A. | en_US |
| dc.contributor.author | Salimzadeh, A. | en_US |
| dc.date.accessioned | 1399-07-30T20:53:33Z | fa_IR |
| dc.date.accessioned | 2020-10-21T20:53:33Z | |
| dc.date.available | 1399-07-30T20:53:33Z | fa_IR |
| dc.date.available | 2020-10-21T20:53:33Z | |
| dc.date.issued | 2005-03-01 | en_US |
| dc.date.issued | 1383-12-11 | fa_IR |
| dc.date.submitted | 2015-08-31 | en_US |
| dc.date.submitted | 1394-06-09 | fa_IR |
| dc.identifier.citation | Forogh, B., Ghasemzadeh, A., Salimzadeh, A.. (2005). Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus. Iranian Journal of Medical Sciences, 30(1), 34-37. | en_US |
| dc.identifier.issn | 0253-0716 | |
| dc.identifier.issn | 1735-3688 | |
| dc.identifier.uri | https://ijms.sums.ac.ir/article_40061.html | |
| dc.identifier.uri | https://iranjournals.nlai.ir/handle/123456789/439053 | |
| dc.description.abstract | The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femoral neck or lumbar spine. Sensitivity, specificity and kappa statistics for DXL were calculated, assuming the DEXA measurement as the gold-standard. The study included 475 women with a mean age of 54±11.9 years. 15% had osteoporosis while 39% were osteopenic (-2.5<T-score between<-1) at the femoral neck or spine. A significant correlation (p<0.001) was found between BMD values as measured by DXL at femoral neck and DEXA at the lumbar spine. Assuming the same T-score cut-off value for the diagnosis osteoporosis and a modified cut-off value for the diagnosis of osteopenia (-2.5<T-score<-1.5), yields a sensitivity of 83% and a specificity of 74% to 86% for the DXL device. In conclusion, BMD measured at the calcaneal bone by DXL, has a good correlation with that measured by axial DEXA.Iran J Med Sci 2005; 30(1): 34-37. Keywords ● Bone mineral densitometry ● Calcaneus ● Osteoporesis | en_US |
| dc.language | English | |
| dc.language.iso | en_US | |
| dc.publisher | Shiraz University of Medical Sciences | en_US |
| dc.relation.ispartof | Iranian Journal of Medical Sciences | en_US |
| dc.title | Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus | en_US |
| dc.type | Text | en_US |
| dc.type | Brief Report(s) | en_US |
| dc.citation.volume | 30 | |
| dc.citation.issue | 1 | |
| dc.citation.spage | 34 | |
| dc.citation.epage | 37 | |