نمایش مختصر رکورد

dc.contributor.authorShariatmadar, H.en_US
dc.contributor.authorKhatamirad, M.en_US
dc.contributor.authorZamani, E.en_US
dc.date.accessioned1399-07-09T11:47:39Zfa_IR
dc.date.accessioned2020-09-30T11:47:39Z
dc.date.available1399-07-09T11:47:39Zfa_IR
dc.date.available2020-09-30T11:47:39Z
dc.date.issued2013-02-01en_US
dc.date.issued1391-11-13fa_IR
dc.date.submitted2012-08-22en_US
dc.date.submitted1391-06-01fa_IR
dc.identifier.citationShariatmadar, H., Khatamirad, M., Zamani, E.. (2013). Pre-Cracked Concrete Shear Strengthened with External CFRP Strips. Journal of Rehabilitation in Civil Engineering, 1(1), 29-38. doi: 10.22075/jrce.2013.3en_US
dc.identifier.issn2345-4415
dc.identifier.issn2345-4423
dc.identifier.urihttps://dx.doi.org/10.22075/jrce.2013.3
dc.identifier.urihttps://civiljournal.semnan.ac.ir/article_3.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/409215
dc.description.abstractIn reinforced concrete design, there are situations where transfer of shear across a specific plane needs to be considered. Examples of such situation include corbels, bearing shoes, ledger beam bearing, and a host of connection between precast concrete elements. In this study, the shear transfer behavior of reinforced concrete is investigated experimentally by conducting test on 6 precracked push-off specimens. The major parameters considered are the amount of reinforcement and externally bonded fiber reinforced polymer fabrics through the shear plane. External strengthening with Fiber Reinforced Polymer (FRP) fabrics is an effective technique for improving the structural performance and life span of the existing reinforced concrete structures. This paper illustrates the result of shear transfer capacity and modes of failure of the precracked reinforced concrete push-off specimens bonded externally with FRP. An experimental investigation was conducted to study the effectiveness of FRP as an external reinforcement. Based on experimental results, the external FRP reinforcement controls the shear slip along the shear plane and crack width. In the unstrengthened push-off specimens, the pre-existing crack along the shear plane will reduce the ultimate shear transfer capacity and increase of shear slip at all load levels. However in strengthened specimens, the external FRP reinforcement will control the increase of slip and increase the ultimate shear stress transfer capacity along the shear plane.en_US
dc.format.extent589
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherSemnan Universityen_US
dc.relation.ispartofJournal of Rehabilitation in Civil Engineeringen_US
dc.relation.isversionofhttps://dx.doi.org/10.22075/jrce.2013.3
dc.subjectShear frictionen_US
dc.subjectPush offen_US
dc.subjectFRPen_US
dc.subjectPre-crackeden_US
dc.titlePre-Cracked Concrete Shear Strengthened with External CFRP Stripsen_US
dc.typeTexten_US
dc.typeRegular Paperen_US
dc.contributor.departmentAssociate Professor, Ferdowsi University of Mashhad, Mashhad, Iranen_US
dc.contributor.departmentPh.D., Student, Ferdowsi University of Mashhad, Mashhad, Iranen_US
dc.contributor.departmentPh.D., Student, Ferdowsi University of Mashhad, Mashhad, Iranen_US
dc.citation.volume1
dc.citation.issue1
dc.citation.spage29
dc.citation.epage38


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد